Rankin Delux RDHP-08 Top Burner Valve NPT In 1/8" Out 3/8"
Specifications:
| Attribute | Details |
|---|---|
| ***For Vulcan Hart Use Ap# 8012180*** | |
| Gas In | 1/8" Npt~ |
| Gas Out | 3/8-27. Off/On, #46 Hood Orifice |
| & Point, Adjustable, Brass | |
| Not Push To Turn Stem | 1-3/16" Long~ |
| D Stem 1/4". Knob | |
| #22-1464 Or #22-1164 Depending On Model. Use #26-2937 To | |
| Convert Valve To 3/8" Cct On Some Models. | |
| Nat Orifice # 26-1117 Is #57, Nat Orifice # 26-1780 Is #56, | |
| Lp Orifice # 26-1080 Is #72. | |
| Anets Broiler Br34-3 | |
| Imperial Broiler Series | Eba, Gd, Icb, Icma, Irb, Isb, Msq, |
| Iab(E)(R)(S). Grill Series | Ihr, Imga. |
| Range Series | Icra, Ihpa, Ihr, Ir, Ispa. |
| Roaster Series | Ipr, Ipra. |
Description
More Information:
- ANETS:P8900-27||BAKERS PRIDE:R3032A ,R3032X||GARLAND:1086588 ,1087697 ,227006 ,9005596 ,9005597 ,9005599 ,G4859-47A ,G4859-57F||MARSAL AND SONS:V-107||MONTAGUE:#34B ,01005-7 ,01006-5 ,02403-1 ,1005-7 ,1006-5 ,14608-0 ,2403-1 ,34A ,34B ,R35||PITCO:P8900-27||RANDELL:DRB-11 ,GB-07 ,RB-11 ,RDGM-08 ,RDHP-08 ,RDHP-8 ,RDHP-E-C-08 ,RDLR-10 ,SUHP-13 ,SUHP-E-C-13 ,TB-11 ,TB-11-A ,TB-11A ,TB-3-11 ,TB3-11||RANKIN DELUX:DRB-11 ,GB-07 ,RB-11 ,RDGM-08 ,RDHP-08 ,RDHP-8 ,RDHP-E-C-08 ,RDLR-10 ,SUHP-13 ,SUHP-E-C-13 ,TB-11 ,TB-11-A ,TB-11A ,TB-3-11 ,TB3-11
Step1: Shut off gas supply and disconnect appliance from power.
Step2: Access the burner valve by removing the control panel.
Step3: Disconnect gas lines from the old valve safely.
Step4: Apply thread sealant and install the new valve in correct orientation.
Step5: Reconnect gas lines and secure all fittings tightly.
Step6: Turn on gas and check for leaks using a soap solution.
Step7: Restore power and test burner operation safely.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Rankin Delux RDHP-08 Top Burner Valve?
Regularly inspect the valve for gas leaks, corrosion, or loose fittings to ensure safe operation. Clean exterior surfaces to prevent grease and debris buildup that can affect performance. Periodically check connections for tightness and proper sealing. Proper maintenance ensures consistent gas flow, safety, and accurate burner performance in commercial kitchen applications.
-
What are common issues with the Rankin Delux RDHP-08 Top Burner Valve?
- Gas leakage from worn seals or loose fittings.
- Difficulty turning valve due to internal wear or debris.
- Irregular flame or inconsistent gas flow.
- Valve sticking or failure to fully open/close due to corrosion or buildup.