Alto-Shaam TT-33432 B10 Thermostat W/3/16" X 16" BULB & D-STEM Knob 60°F-200°F

SKU: TT-33432 Brand: Availability:
In Stock
(0)

C$ 218.54 Price reduced from C$ 294.35
Save C$ 75.81


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Specifications:

Attribute Details
T'Stat B10, Temp 60-200, Cap 84", Bulb 3/16" X 16"
D-Stem Flat Down
Use Knob A928, K-192, # 221067 Off-200-60
If Pointer Dial Is Needed Use Oem # Kn-26568
Alto-Shaam
Warmer 1000Up, 1200-Up, 1200-Ups, 1200-Up/Sr

Description

The Alto-Shaam TT-33432 B10 Thermostat serves as a precision temperature control partwhich operates on kitchen equipment. The partcombines a 3/16" x 16" bulb with an 84" capillary tube to deliver accurate heat control between 60°F and 200°F. The thermostat improves both energy efficiency and food quality at Hightemperatures which leads to superior food consistency. The partcombines durable material construction with reliable performance Features that make it perfect for challenging kitchen environments by providing precise temperature control which extends equipment life and maintains operational consistency.

More Information:

  • ALTO-SHAAM:ALTTT33432 ,TT-33432 ,TT33432||U-LINE:Z87147-84

Step1: Disconnect electrical power and confirm the unit is fully cooled before starting work.

Step2: Remove the control panel to access the thermostat body and sensing bulb assembly.

Step3: Disconnect and label wiring, then remove the old bulb from its retaining bracket.

Step4: Install the new thermostat, position the bulb in the same cavity location, and secure it properly.

Step5: Reconnect wiring, reassemble the panel, restore power, and check smooth temperature control across the full range.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Alto-Shaam TT-33432 Thermostat?

    Inspect the thermostat bulb and capillary tube regularly for kinks or damage. Keep electrical connections tight and free from corrosion to ensure stable control. Clean the sensing area gently to avoid debris buildup. Regular calibration checks assist maintain accurate temperature regulation and better equipment operation.

  • What are common issues with the Alto-Shaam TT-33432 Thermostat?

    • Inaccurate temperature control or drifting readings during operation.
    • Faulty or stuck knob preventing proper adjustment.
    • Damaged bulb or capillary causing loss of sensing response.
    • Intermittent heating due to weak electrical contact or internal damage.