Description

The Imperial 30030 Thermocouple 18 inch 20-30 mV 1980 Series is a flame detection safety element that is installed in commercial gas cooking appliances. It operatesby producing a small electrical voltage when it is warmed by pilot flame, and the control system can check the presence of the flame and adjust the amount of gas flowing. This is fitted in burner assembly, and it constantly checks the conditions of ignition. It is also a part of the appliance that helps in the secure operation.

More Information:

  • AMERICAN RANGE:10485 ,A11100 ,AMRA11100||ANETS:ANEP8900-32 ,P8900-32||APW WYOTT:1473103 ,AS-1473103||CECILWARE:F002A ,F002F ,GMF002A ,GMF002F||COMSTOCK CASTLE:17005 ,COM17005 ,COMT46 ,T46||DYNAMIC COOKING SYSTEMS:13007 ,13007-01||GARLAND:1019418 ,1029410 ,1307401 ,1415000 ,227002 ,227122 ,227183 ,4518817 ,G01575-1 ,GL1019418 ,GL1029410 ,GL1415000 ,GL227183 ,GLG01575-1||HOBART:00-920325 ,14268 ,412788-1 ,714268 ,920325||IMPERIAL:1121 ,30030 ,IMP1121||JADE RANGE:460-126-000 ,4612600000 ,4620100000||ROYAL RANGE:2175 ,2179||SOUTHBEND:1163868 ,1683868 ,SOU1163868 ,SOU1683868||STAR MFG:2J-6726 ,2J6726 ,6726 ,H456||STERO:STA2J-6726 ,STA2J6726 ,STA6726 ,STAH456||TRI-STAR:310210 ,TRS310210||U-LINE:1980-018||VULCAN HART:00-920325 ,14268 ,412788-1 ,714268 ,920325

Step1: Turn off gas and power, cool appliance.

Step2: Remove access panel and disconnect old thermocouple from valve and pilot.

Step3: Route new thermocouple ensuring tip sits in pilot flame correctly.

Step4: Secure connection to gas valve and tighten mounting hardware.

Step5: Restore gas, ignite pilot, check stable flame and safety shutdown.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Imperial 30030 Thermocouple?

    Check the thermocouple periodically for dirt, corrosion, or loose fittings that may affect performance. Clean the tip carefully to maintain proper flame sensing. Ensure it is correctly positioned in the pilot flame. Always turn off the gas supply before performing maintenance operation.

  • What are common issues with the Imperial 30030 Thermocouple?

    • Weak or inconsistent millivolt signal output.
    • Improper alignment with pilot flame.
    • Loose or damaged connection threads.
    • Heat damage or residue buildup on the sensor.