Garland 2200602 Thermocouple 24"

SKU: 2200602 Brand: Availability:
In Stock
(0)

C$ 65.04 Price reduced from C$ 102.50
Save C$ 37.46


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Specifications:

Attribute Details
24" Metric Thermocouple, Sit Type, 20-30 Mv
9Mm Thread (M9-1.0)
Garland
Oven Gd24Gff,
G24-15Hfsd, Gd-152Hff, Gd-303Hff, Gd-304-Hff, Ms54R, Ms54Rc,
Ms54Rce, Ms54Re, Ms54S, Ms54Se, Ms54T, Ms54Te, Mst43R,
Mst43Rc, Mst43Rce, Mst43Re, Mst43S, Mst43Se, Mst43T,
Mst43Te, Mst44R, Mst44Rc, Mst44Rce, Mst44Re, Mst44S,
Mst44Se, Mst44T, Mst44Te, Mst4S, Mst4Se, Mst4T, Mst4Te,
Mst54R, Mst54Rc, Mst54Rce, Mst54Re, Mst54S, Mst54Se, Mst54T,
Mst54Te

Description

The Garland 2200602 Thermocouple 24" is a sensor that is intended to be used in other compatible commercial cooking equipment. It also measures the temperature inside the appliance and transmits a signal to the control system to control the burner or heating element. The thermocouple is mounted on the burner assembly and it is normally changed when it stops sensing the temperature correctly or when it stops giving the required signal. The thermocouple is 24 inches to ensure that the operation is maintained by assisting in the maintenance of the right temperature and eliminating overheating during the cooking activities.

More Information:

  • GARLAND:2200602 ,GL2200602

Step1: Turn off oven power and gas supply, and allow unit to cool completely to ensure safety.

Step2: Remove access panel and place existing thermocouple near burner assembly.

Step3: Disconnect old threaded thermocouple using proper tools.

Step4: Install SIT Type thermocouple, hand-tighten then secure.

Step5: Reconnect leads and ensure proper alignment and secure fit.

Step6: Restore power and test ignition and flame sensing for proper operation.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Garland 2200602 Thermocouple?

    Inspect the thermocouple for grease buildup, corrosion, or loose connections that could impact performance. Clean the sensing tip to ensure accurate flame detection. Verify proper placement in the pilot flame. Always disconnect the gas supply before servicing to ensure better handling.

  • What are common issues with the Garland 2200602 Thermocouple?

    • Pilot flame not staying lit accurately.
    • Low or unstable millivolt output.
    • Misalignment with the pilot flame.
    • Worn or damaged thread connections.