Garland 2195100-GAR Range Surface Heater 1250W 208V

SKU: 2195100-GAR Brand: Availability:
Out of Stock
(0)

C$ 121.71 Price reduced from C$ 266.50
Save C$ 144.79


Have a Question? +1 (866) 963-0907 / (630) 326-8602

Specifications:

Attribute Details
Garland Listed As 6-1/2" Element, 208V, 1250W.
Surface Element, [ 208V 1250W ][ 6" Dia. Od Element ]
[Terminals {Screw }
Does Not Have Plastic Terminal End.
Garland 680 Series After 12/92
684, 684Rc, 686Rc, E22-12H, E684, E686

Description

The Garland 2195100-GAR Range Surface Heater is made to be used as a component of a commercial cooking appliance. It has a rating of 1250W at 208 V, it provides consistent heat to the cooking area and aids to maintain the proper temperature distribution. This heater enables cookware to get an equal amount of heat that can be used to ensure consistent cooking performance. This is usually replaced when servicing to ensure that the heating works normally. In the range system, the heater aids in the stable operation and allows the controlled heat production during the cooking time.

More Information:

  • GARLAND:2195100 ,2195100-GAR

Step1: Disconnect power at the breaker and allow the appliance to cool completely.

Step2: Remove the access panel to expose the surface element.

Step3: Disconnect wires from the old heater’s screw terminals.

Step4: Remove mounting brackets or clips and lift out the old element.

Step5: Position the new heater, secure it, and reconnect wiring firmly.

Step6: Restore power and test for even heating and proper operation.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Garland 2195100-GAR Surface Heater?

    Inspect the heater element for debris, cracks, or discoloration. Ensure electrical connections are tight and free of corrosion. Test operation periodically, and disconnect power before performing any service.

  • What are the common issues with the Garland 2195100-GAR Surface Heater?

    • Heater element burnout.
    • Loose or corroded electrical connections.
    • Uneven heating.
    • Cracks or physical damage to the element.