Cleveland FK1043061 Steamer Element 300W 230-240V
Specifications:
| Attribute | Details |
|---|---|
| Drying Element | |
| [ 240V 300W 1Ph ] [ 2.75" Oc Bolt Holes, | |
| 9 5/8" Inside Length ] [Terminals {Ring }, | |
| With Gasket | |
| Gasket Only # 32-1319 | |
| Cleveland Steamer 21-Cet-8, 21-Cet-16, 10 Pan Units |
Description
More Information:
- CLEVELAND:1040591 ,1043061 ,FK1043061
Step1: Disconnect power and allow unit to cool completely before servicing.
Step2: Remove access panel from unitr and locate old heating element, ensure water is drained.
Step3: Disconnect wiring terminals, noting positions for reassembly, tag wires if needed.
Step4: Unscrew and remove faulty element carefully, avoid sharp edges.
Step5: Install new element and secure firmly, ensure correct rating.
Step6: Reconnect wiring, replace panel, restore power and test operation, check for proper heat-up.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Cleveland FK1043061 Element?
Regularly inspect the steamer element for scale buildup or residue and clean it using a manufacturer-approved descaling solution. Ensure electrical connections are secure and free from corrosion. Routine maintenance supports maintain heating efficiency and prevents overheating. Always disconnect power before servicing for safety.
-
What are common issues with the Cleveland FK1043061 Element?
- Element not steamer heating properly or uneven heat output.
- Electrical connection failures or loose wiring.
- Scale buildup causing reduced efficiency.
- Burnout due to voltage fluctuations.
- Tripping of circuit breakers during operation.