T&S Brass 000801-25 Spindle Left Hand
Specifications:
| Attribute | Details |
|---|---|
| T&S Spindle For B-1100 Faucets | |
| Cold For Deck Faucet | |
| Hot For Wall Faucet |
Description
More Information:
- T&S BRASS:000801-25 ,000801-25M ,15X ,801-25 ,801-25M ,TS000801-25 ,TS000801-25M ,TS15X ,TS801-25 ,TS801-25M
Step1: Shut off water supply and open faucet to release pressure and avoid injury.
Step2: Remove handle and bonnet to expose the valve stem and spindle assembly.
Step3: Unscrew old spindle, inspect seat, and clean mineral buildup if present.
Step4: Install new spindle, apply light lubricant, and thread securely into place.
Step5: Reassemble handle, turn water back on slowly, and check for leaks.
Step6: Ensure smooth operation and re-tighten if dripping occurs.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the T&S Brass 000801-25 Spindle?
Inspect the spindle regularly for mineral buildup and wear. Clean deposits with mild descaling solution and ensure smooth rotation. Lubricate moving parts with proper grease and replace seals if leakage occurs. Regular checks ensure accurate water control and performance.
-
What are common issues with the T&S Brass 000801-25 Spindle?
- Hard-to-turn spindle due to mineral buildup.
- Corrosion or scaling affecting internal components.
- Thread stripping or loose fit causing unstable operation.
- Handle wobble or inconsistent flow control.