Southbend 1173493 Range Safety Valve 3/8" FPT X 3/16" Tube

SKU: 1173493 Brand: Availability:
In Stock
(0)

C$ 221.83 Price reduced from C$ 410.81
Save C$ 188.98


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Specifications:

Attribute Details
[Nat/Lp] [ 3/8"Fpt } [3/16" Cct Pilot In/Out ]
[ Safety ] [Width 2-1/2" ] [ Brand Baso Mfg# H15Hr-2 ]
[ 160,000 Btu ]
American Range, Duke, Imperial, Southbend
Garland Oven 44-40R, Gv28. Series G30A, G280, Gv280,
H280 Including H28(S).Hi28
Montague Oven Pizza 13P-1, 14P-1, 23P-2, 24P-2~
Bake/Roast 12B-1,12R-1, 13B-1, 13R-1,22C-2,23C-2~
Vectaire 115(A,S,X,Z).12R-1, 13B-1, 13R-1, 22C-2,23C-2
Us Range Grill Rgt-Bka-2436-1, Tb-24Gg.
Oven P-4-20, S-102626, Series P, Px, Sunfire < 9-5-00.
Series 836 Cuisine, Performer Ii & Pf.
Vulcan 7019A-1B

Description

The Southbend 1173493 Safety Valve is an essential part that is meant for the Range appliances, it has 3/8” FPT and 3/16” tube connection. This prevents gas flow and leakage, making it safe to be used in kitchens thus improving on the safety available valves. It works by quickly turning off the gaseous supply if the gas supply is broke or has an unusual pressure so that home appliances run safely. Other advantage are as follows; reduce risk, enhance on regulatory provisions and the dependability of kitchen appurtinances making the part suitable for food service industries.

More Information:

  • AMERICAN RANGE:A80000||COMSTOCK CASTLE:17018||DUKE:213518||GARLAND:1415701 ,1415702 ,1415703 ,227071 ,253490-1 ,CK1415703 ,CK253490-1 ,CK253490-2 ,G01969-1 ,G01969-1H ,GL1415701 ,GL1415702 ,GL1415703 ,GLCK253490-2||IMPERIAL:2138-1||MONTAGUE:34604-7||SOUTHBEND:1173493

Step1: Turn off the gas supply and unplug the range before starting.

Step2: Remove the access panel to reach the existing safety valve.

Step3: Disconnect the gas line and any electrical connections from the old valve.

Step4: Remove the old valve and mount the new one in the same position.

Step5: Reconnect the gas line and wiring securely.

Step6: Replace the panel and restore the gas supply.

Step7: Test for leaks and proper operation before regular use.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Southbend 1173493 Safety Valve?

    Inspect the range valve for proper operation and check all gas connections for leaks. Ensure the valve opens and closes smoothly and that any attached sensors or actuators are clean and unobstructed. Power off the gas supply before servicing.

  • What are common issues with the Southbend 1173493 Safety Valve?

    • Valve sticks or fails to actuate.
    • Gas leaks at threaded connections.
    • Slow or inconsistent burner ignition.
    • Corrosion or debris interfering with operation.