Montague R35 Charbroiler Top Burner Valve NPT In 1/8" Out 3/8"
Specifications:
| Attribute | Details |
|---|---|
| ***For Vulcan Hart Use Ap# 8012180*** | |
| Gas In | 1/8" Npt~ |
| Gas Out | 3/8-27. Off/On, #46 Hood Orifice |
| & Point, Adjustable, Brass | |
| Not Push To Turn Stem | 1-3/16" Long~ |
| D Stem 1/4". Knob | |
| #22-1464 Or #22-1164 Depending On Model. Use #26-2937 To | |
| Convert Valve To 3/8" Cct On Some Models. | |
| Nat Orifice # 26-1117 Is #57, Nat Orifice # 26-1780 Is #56, | |
| Lp Orifice # 26-1080 Is #72. | |
| Anets Broiler Br34-3 | |
| Imperial Broiler Series | Eba, Gd, Icb, Icma, Irb, Isb, Msq, |
| Iab(E)(R)(S). Grill Series | Ihr, Imga. |
| Range Series | Icra, Ihpa, Ihr, Ir, Ispa. |
| Roaster Series | Ipr, Ipra. |
Description
More Information:
- ANETS:P8900-27||BAKERS PRIDE:R3032A ,R3032X||GARLAND:1086588 ,1087697 ,227006 ,9005596 ,9005597 ,9005599 ,G4859-47A ,G4859-57F||MARSAL AND SONS:V-107||MONTAGUE:#34B ,01005-7 ,01006-5 ,02403-1 ,1005-7 ,1006-5 ,14608-0 ,2403-1 ,34A ,34B ,R35||PITCO:P8900-27||RANDELL:DRB-11 ,GB-07 ,RB-11 ,RDGM-08 ,RDHP-08 ,RDHP-8 ,RDHP-E-C-08 ,RDLR-10 ,SUHP-13 ,SUHP-E-C-13 ,TB-11 ,TB-11-A ,TB-11A ,TB-3-11 ,TB3-11||RANKIN DELUX:DRB-11 ,GB-07 ,RB-11 ,RDGM-08 ,RDHP-08 ,RDHP-8 ,RDHP-E-C-08 ,RDLR-10 ,SUHP-13 ,SUHP-E-C-13 ,TB-11 ,TB-11-A ,TB-11A ,TB-3-11 ,TB3-11
Step1: Turn off gas supply and allow burner to cool completely before starting work.
Step2: Remove old valve, noting inlet and outlet connections orientation.
Step3: Apply approved thread sealant to NPT fittings and align new valve correctly.
Step4: Tighten fittings securely without over-torquing and ensure proper seating alignment.
Step5: Restore gas supply, check for leaks using soapy water, and test operation safely before use.
Step6: Ensure proper ventilation during installation and avoid open flames.
Step7: Verify flame stability after installation and recheck fittings after operation.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Montague R35 Top Burner Valve?
Clean valve ports regularly to prevent grease or carbon buildup affecting flow control. Inspect threads and seals for wear or damage. Ensure smooth valve operation and check for leaks to maintain consistent burner performance and better gas regulation.
-
What are common issues with the Montague R35 Top Burner Valve?
- Stiff or stuck valve handle reducing flow control.
- Gas leakage from worn internal seals.
- Irregular flame due to partial blockage.
- Thread damage causing poor fitting connection.