Pitco PTP5047541 Fryer Coaxial Thermopile 36" 250-750 MV
Specifications:
| Attribute | Details |
|---|---|
| 36" Coaxial Thermopile, 250-750 Mv | |
| Coaxial Thermopile Threads = 3/8"-32. | |
| Robertshaw 1951-53F | |
| Vulcan 1Grc35, 1Grc45, 1Grc65, 1Grd45, 1Grd65, 1Grs35, | |
| 1Grs45, 1Grs65, Gr35F, Gr45F, Gr65F, Gr85F, Grc35F, Grc45F, | |
| Grc65F, Grc85F, Grd35F, Grd45F, Grd65F, Grd85F, Grs35F, | |
| Grs45F, Grs65F, Grs85F | |
| Wolf Fryer Wtf-42, Ss-Wtf-42 | |
| Grill Tmm (36, 37, 38) |
Description
More Information:
- ANETS:P8905-38||DEAN:1897 ,810-0162 ,8100162||DYNAMIC COOKING SYSTEMS:13257 ,DCS13257||FRYMASTER:1897 ,810-0162 ,8100162 ,FM1897 ,FM810-0162 ,FM8100162||GARLAND:1093418 ,1292900 ,1577001 ,1897 ,F810-0162 ,F810-0617 ,GL1093418 ,GL1292900 ,GL1577001 ,GLF810-0162||HOBART:00-348358-00001 ,00-410839-00001 ,00-711335 ,110839-1 ,11335 ,348358-1 ,410839-00001 ,410839-1 ,711335||KEATING:002567 ,2567 ,H00340H ,KEA2567 ,KEAH00340H||PITCO:P5047541 ,P5047542 ,P8905-38 ,PTP5047541 ,PTP5047542||SOUTHBEND:1054300 ,1056400 ,SOU1054300 ,SOU1056400||U-LINE:1951-536 ,1951-53F||VULCAN HART:00-410839-00001 ,00-711335 ,110839-1 ,11335 ,410839-00001 ,410839-1 ,711335 ,VH110839-1 ,VH410839-1
Step1: Turn off gas and electrical supply, and allow fryer to cool completely before servicing.
Step2: Remove access panel and disconnect old thermopile wiring carefully from control box.
Step3: Install new thermopile in pilot assembly, securing mounting bracket into position.
Step4: Reconnect wiring to control module, ensuring tight, correct polarity according to manufacturer guidelines.
Step5: Restore gas supply, relight pilot, and test flame signal for stable operation, check for proper ignition.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Pitco PTP5047541 Coaxial Thermopile?
Inspect the fryer thermopile regularly for secure mounting and clean burner flame contact to ensure proper millivolt output. Check wiring connections for corrosion or looseness during fryer servicing. Replace the unit if output becomes weak or inconsistent. Proper maintenance ensures stable gas valve operation and better fryer ignition.
-
What are common issues with the Pitco PTP5047541 Coaxial Thermopile?
- Weak or no millivolt output causing ignition failure.
- Pilot flame not properly heating thermopile.
- Loose or corroded electrical connections.
- Intermittent gas valve holding issues.
- Dirty or misaligned burner affecting signal generation.