Pitco PT60113501 Fryer Natural Gas Safety Valve 24V VR8204

SKU: PT60113501 Brand: Availability:
In Stock
(0)

C$ 321.25 Price reduced from C$ 540.85
Save C$ 219.60


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Specifications:

Attribute Details
Ramon Hernandez 3/5/2021 6 35 Am
Comment
1/2" Inlet & Outlet
(2) Fitting Adapter Flared 15/16-16 Un-2A X 1/2 Fnpt Brass

Description

Pitco PT60113501 Fryer Natural Gas Safety Valve 24V VR8204 is an essential part which is used to control the flow of gas during the frying process. This valve controls the flow of the gas and also has the added advantage of safety in that in the event of a problem it will close off the supply of the gas. They include enhanced cooking efficiency, energy conservation and enhanced safety profile. Designed specifically for restaurant and food service industries to obtain a better component fit and help to obtain longer-life on fryer equipment and improved food quality.

More Information:

  • ANETS:60113501-CL||MAGIKITCH'N:60113501 ,60113501-C ,60113501-CL||PITCO:60113501 ,60113501-C ,60113501-CL ,60113501C ,PT60113501 ,PT60113501-C ,PT60113501C

Step1: Turn off gas supply and disconnect fryer power to ensure safety.

Step2: Remove access panel and disconnect old safety valve wiring and fittings.

Step3: Install new valve, aligning fittings and tightening securely.

Step4: Reconnect wiring and gas line, ensuring proper seals.

Step5: Restore power, turn on gas, and check for leaks using soapy solution.

Step6: Wear protective gloves and ensure ventilation.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Pitco PT60113501 Valve?

    Inspect the Pitco PT60113501 Valve regularly for grease, debris, or corrosion. Clean the valve body and ensure connections are tight to maintain proper gas flow and safe operation.

  • How do I install the Pitco PT60113501 Valve?

    • Turn off the gas supply and power to the fryer.
    • Remove the existing valve, noting the orientation and connection points.
    • Mount the Pitco PT60113501 Valve in the designated position on the burner manifold.
    • Connect the gas line securely using approved fittings.
    • Reconnect any electrical or pilot components as per the wiring diagram.
    • Turn on gas supply and test the valve for proper operation, checking for leaks with a soapy water solution.

  • What are common issues with the Pitco PT60113501 Valve?

    Common issues include sticking or failure to open/close due to debris, leaks at connection points, or pilot ignition problems.

  • What maintenance is required for the Pitco PT60113501 Safety Valve?

    Inspect the safety valve regularly for grease, carbon, and debris buildup that may affect gas regulation and ignition performance. Ensure all electrical connections remain tight, clean, and corrosion-free. Verify consistent opening, stable gas flow, and proper shutoff response during repeated fryer heating cycles without leakage or delay.

  • What are the common issues with the Pitco PT60113501 Safety Valve?

    • Valve failing to open properly.
    • Gas leakage occurring at seals.
    • Delayed ignition response.
    • Electrical connection failure.
    • Inconsistent shutoff operation.