Southbend 4-LLP1 Range Water Level Probe W/ 1-1/2" Under Nut Thread 3/8" MPT

SKU: 4-LLP1 Brand: Availability:
In Stock
(0)

C$ 343.23 Price reduced from C$ 400.81
Save C$ 57.58


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Specifications:

Attribute Details
Probe (Water Level, 3/8" Mpt, 1-1/2" Under Nut Thread
3 3/8" Total Length
Cleveland
Kettle Series Kel, Kep, Ket, Kgl, Kgm, Kgt, Sse.
Mixer Series Mket.

Description

The Southbend 4-LLP1 Water Level Probe is an essential measuring tool for checking the levels in different Ranges appliances. It has a 1-1/2” under nut thread and a 3/8” MPT connection which makes it easy to install and efficient in its function. It works through sensing the water levels and displays the right readings that assist in the right cooking environment. Some of the advantages of using this include; increased effectiveness in food preparation, avoids cases of overflows, and increased safety in the food preparation area. It is suitable for use in the kitchen and will enhance the generation of standard results when cooking while at the same time protecting the equipment from potential damage.

More Information:

  • ACCUTEMP:AC-4-LLP1||BLODGETT:40930 ,BL40930||CLEVELAND:CLEKE50556 ,CLEKE50556-1 ,KE50556 ,KE50556-1||CROWN STEAM:3738-15 ,4-LLP1||GROEN:CROWN-4-LLP1||HOBART:00-817233 ,00-881981 ,1723300 ,817233 ,881981||MARKET FORGE:08-4864 ,084864 ,10-7935 ,97-5425||SOUTHBEND:4-LLP1 ,4LLP1 ,SOU4LLP1||VULCAN HART:00-817233 ,00-881981 ,1723300 ,817233 ,881981

Step1: Turn off boiler power and water supply at main valve using lockout tagout.

Step2: Depressurize system completely before servicing to ensure safety.

Step3: Remove old probe and clean fitting threads thoroughly.

Step4: Apply thread sealant to MPT threads evenly per manufacturer specs.

Step5: Insert new probe into nut fitting and align properly.

Step6: Tighten securely without over-torquing to avoid damage and prevent cracking.

Step7: Restore water, power, and test operation for leaks and system function.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Southbend 4-LLP1 Water Level Probe?

    The range probe should be checked regularly for mineral buildup and cleaned to ensure accurate water level detection. Inspect threads and connections for leaks or corrosion. Ensure proper installation alignment and avoid overtightening during servicing to prevent thread damage.

  • What are common issues with the Southbend 4-LLP1 Water Level Probe?

    • Incorrect water level readings.
    • Mineral buildup affecting conductivity.
    • Leaks around threaded connection.
    • Corroded or damaged probe surface.
    • Poor electrical contact causing inconsistent operation.