Rankin Delux RDLR-06C Pressure Regulator NAT 3/4" 3"-6"WC 1/2PSI

SKU: RDLR-06C Brand: Availability:
In Stock
(0)

C$ 55.57 Price reduced from C$ 86.16
Save C$ 30.59


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Specifications:

Attribute Details
Nat Gas, 3/4" Fpt Gas In/Out, 3"- 6" Wc, 1/2 Psi
250,000 Btu, Maxitrol Rv48L-66-0001 Preset At Factory To 3.5
American Range
Bakers Pride Oven Where Applicable.
Blodgett Oven Series 900, 999, 1000, Bcg, Fa, Gzl.
Garland Griddle Series Gd, Broiler G-80, Ir
Groen Kettle Ah/1, Ah/1E
Imperial Oven Ir,Ihr
Keating Fryer Bb, Cc & Ts 18" & Up.
Southbend Oven Series 300.
Griddle Series Sg Counter Top
Vulcan Broiler, Grill, Warmer Where Applicable.
Fryer 7594G, Oven Series 7000
Range 24L, 36L/Lc, 48L/Lc, 148L/Lc, 60L/Lc/Lcc, 161L/Lc,
260L/Lc/Lcc.

Description

The Rankin Delux RDLR-06C Pressure Regulator is a gas control component that is used to control the flow of natural gas in commercial cooking appliances. It also has a constant outlet pressure of 3 to 6 inches of water column which provides stable burner operation and safe operation of the appliances. It is installed in the gas supply line of foodservice equipment and is used to regulate the supply of gas to the heating system. This regulator has a 3/4-inch connection and 1/2 PSI rating, and it is necessary to ensure that the combustion conditions are kept correct and that the regulator operates efficiently in the kitchen of a professional conditions.

More Information:

  • AMERICAN RANGE:10480 ,A80110||BAKERS PRIDE:AS-M1008A ,BKPM1008A ,M1008A ,M1008X||BLODGETT:04527 ,4527 ,4589 ,5118 ,90013 ,BL4527 ,BL4589 ,BL5118 ,BL90013 ,Z1160205||CECILWARE:GML053A ,GML053F ,L053A ,L053F||CLEVELAND:2127502 ,2127503 ,CLE2127503 ,KE54618-2||DORMONT:R48N42-0306-3.5||DYNAMIC COOKING SYSTEMS:13006-3||GARLAND:1019000 ,1019003 ,1019010 ,1019012 ,2127502 ,2127503 ,228052-13 ,G01740 ,GL1019000 ,GL1019003 ,GL1019010 ,GL1019012 ,GL2127502 ,GLG01740||GRINDMASTER:L053A||GROEN:000345 ,101570A ,Z000345||HOBART:00-408279-00001 ,00-408279-00009 ,00-408279-00020 ,00-408279-00022 ,00-408279-00024 ,00-408279-00025 ,108279-1 ,108279-20 ,108279-22 ,108279-9 ,19954 ,20024 ,408279-00001 ,408279-00009 ,408279-00020 ,408279-00022 ,408279-00024 ,408279-00025 ,408279-1 ,408279-20 ,408279-22 ,408279-24 ,408279-25 ,408279-9 ,719954 ,720024 ,720064||IMPERIAL:1050 ,IMP1050||JADE RANGE:460-135-000 ,4613500000||KEATING:004236||LANG:2V-80501-04 ,80501-04||MAGIKITCH'N:2701-0028200 ,270100282 ,27010028200 ,37N ,MK2701-0028200 ,MK270100282 ,MK27010028200 ,MK37N ,MKRP1011 ,RP1011||MONTAGUE:01039-1 ,1039-1 ,2139-3 ,R96-1||NIECO:2195||RANDELL:RDLR-06C ,RDLR06-3/4||RANKIN DELUX:GT15 ,RANGT15 ,RANRDCM02 ,RDCM02 ,RDLR-06C ,RDLR06-3/4||ROYAL RANGE:1618||SOUTHBEND:1160164 ,1160176 ,1160205 ,SOU1160164 ,SOU1160176 ,SOU1160205||STAR MFG:2J-0028200 ,2J-39007 ,2J39007 ,2V-80501-04 ,59007||STERO:WEL2J-39007 ,WEL2J39007||VULCAN HART:00-408279-00001 ,00-408279-00009 ,00-408279-00020 ,00-408279-00022 ,00-408279-00024 ,00-408279-00025 ,108279-1 ,108279-20 ,108279-22 ,108279-9 ,19954 ,20024 ,408279-00001 ,408279-00009 ,408279-00020 ,408279-00022 ,408279-00024 ,408279-00025 ,408279-1 ,408279-20 ,408279-22 ,408279-24 ,408279-25 ,408279-9 ,719954 ,720024 ,720064 ,844516-8 ,VH108279-1 ,VH408279-1 ,VH408279-20 ,VH844516-8

Step1: Turn off the natural gas supply and disconnect electrical power to the appliance.

Step2: Remove the existing regulator and inspect gas piping for wear or debris.

Step3: Apply approved gas thread sealant to the male pipe threads only.

Step4: Install the new regulator with the directional flow arrow pointing toward the equipment.

Step5: Tighten the connections securely without damaging the fittings.

Step6: Restore the gas supply and check all joints with a soap-and-water solution for leaks.

Step7: Verify gas pressure is set between before placing the appliance into operation.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Rankin Delux RDLR-06C Pressure Regulator?

    Regularly inspect the regulator for leaks and ensure consistent gas pressure output. Keep the unit clean and free from grease buildup that may affect internal components. Check all fittings for tightness and secure sealing. Replace worn parts if pressure regulation becomes unstable.

  • What are common issues with the Rankin Delux RDLR-06C Pressure Regulator?

    • Inconsistent outlet gas pressure.
    • Leakage at inlet or outlet connections.
    • Internal diaphragm wear or failure.
    • Reduced flow efficiency due to blockage.
    • Difficulty maintaining stable pressure under load.