Specifications:

Attribute Details
***For Vulcan Hart Use Ap# 8012180***
Gas In 1/8" Npt~
Gas Out 3/8-27. Off/On, #46 Hood Orifice
& Point, Adjustable, Brass
Not Push To Turn Stem 1-3/16" Long~
D Stem 1/4". Knob
#22-1464 Or #22-1164 Depending On Model. Use #26-2937 To
Convert Valve To 3/8" Cct On Some Models.
Nat Orifice # 26-1117 Is #57, Nat Orifice # 26-1780 Is #56,
Lp Orifice # 26-1080 Is #72.
Anets Broiler Br34-3
Imperial Broiler Series Eba, Gd, Icb, Icma, Irb, Isb, Msq,
Iab(E)(R)(S). Grill Series Ihr, Imga.
Range Series Icra, Ihpa, Ihr, Ir, Ispa.
Roaster Series Ipr, Ipra.

Description

The Rankin Delux DRB-11 Top Burner Valve NPT In 1/8" and 3/8" is a flow-controlling valve that is used to control the supply of fuel in a gas system of distribution. It acts by regulating the opening of an internal passage, whereby there is controlled inlet-outlet flow. It is an inline valve that should be used in cases where the delivery has to be constant and controlled. Its contribution to the system is to provide proper flow control, safe usage, and predictable operation.

More Information:

  • ANETS:P8900-27||BAKERS PRIDE:R3032A ,R3032X||GARLAND:1086588 ,1087697 ,227006 ,9005596 ,9005597 ,9005599 ,G4859-47A ,G4859-57F||MARSAL AND SONS:V-107||MONTAGUE:#34B ,01005-7 ,01006-5 ,02403-1 ,1005-7 ,1006-5 ,14608-0 ,2403-1 ,34A ,34B ,R35||PITCO:P8900-27||RANDELL:DRB-11 ,GB-07 ,RB-11 ,RDGM-08 ,RDHP-08 ,RDHP-8 ,RDHP-E-C-08 ,RDLR-10 ,SUHP-13 ,SUHP-E-C-13 ,TB-11 ,TB-11-A ,TB-11A ,TB-3-11 ,TB3-11||RANKIN DELUX:DRB-11 ,GB-07 ,RB-11 ,RDGM-08 ,RDHP-08 ,RDHP-8 ,RDHP-E-C-08 ,RDLR-10 ,SUHP-13 ,SUHP-E-C-13 ,TB-11 ,TB-11-A ,TB-11A ,TB-3-11 ,TB3-11

Step1: Turn off gas supply and power and ensure appliance is cool.

Step2: Remove old valve and clean inlet/outlet threads.

Step3: Apply a pipe sealant to fittings.

Step4: Mount new valve in correct flow direction and tighten securely.

Step5: Reconnect burner assembly and ensure alignment.

Step6: Perform leak test with soapy water and check all joints.

Step7: Restore gas and test burner operation carefully.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Rankin Delux DRB-11 Top Burner Valve?

    Inspect and clean the valve regularly to prevent grease buildup and blockage. Ensure proper tightening of connections to avoid gas leaks. Lubricate moving components if required and check for smooth burner control operation.

  • What are common issues with the Rankin Delux DRB-11 Top Burner Valve?

    • Gas leakage from worn seals or loose fittings.
    • Irregular flame or low heat due to partial blockage.
    • Difficulty turning knob caused by internal damage or debris.
    • Valve sticking or inconsistent burner response during operation.