Crown Steam PE-139 Signal Light 3/8" X 1-5/16" Red 125V

SKU: PE-139 Brand: Availability:
In Stock
(0)

C$ 30.29 Price reduced from C$ 33.41
Save C$ 3.12


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Specifications:

Attribute Details
Signal Light
125V [ Fits Hole 3/8" X 1-5/16" ] [1/4" Tabs ] [Color Red]
[ Type Hat Flat ][ Bezel Chrome] [ Fastener Lock Tabs]
Lincoln Proofer/Steamer Wear-Ever Fresh-O-Matic
Us Range Grill Tb-24Gg

Description

The Crown Steam PE-139 Signal Light 3/8 X 1-5/16 Red 125 V is intended to be used in other compatible commercial kitchen equipment. This red signal light is 3/8 inch by 1-5/16 inches and rated at 125 volts to give a visual signal of the operational status alerting the operators to the active cycles. The control panel is attached to the electrical system of the appliance and when the circuit is energized, the control panel lights up. The signal light is commonly used in other commercial foodservice equipment and is used to support the operation of kitchen equipment.

More Information:

  • ACCUTEMP:AC-4996-2||BLODGETT:15549 ,42415 ,43240||CROWN STEAM:4996-2 ,PE-139||DEAN:807-1060 ,8071060||FRYMASTER:807-0049 ,807-1060 ,8070049 ,8071060 ,FM807-1060 ,FM8071060||GARLAND:228007-5||HOBART:00-345751-00001 ,00-844485 ,345751-1 ,844485||LINCOLN:350605||MARKET FORGE:97-5709||NEMCO:350605||SOUTHBEND:1161450 ,1161650 ,4996-2 ,PE-139||VULCAN HART:00-345751-00001 ,00-844485 ,345751-1 ,844485

Step1: Disconnect electrical power and confirm unit is fully de-energized.

Step2: Remove control panel to access existing old indicator light assembly.

Step3: Label and disconnect wiring from the old signal light terminals.

Step4: Unscrew retaining nut and remove faulty light from mounting hole.

Step5: Install new light, secure tightly, and reconnect wires to matching terminals.

Step6: Restore power and test illumination to ensure proper ON/OFF indication and safe operation.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Crown Steam PE-139 Signal Light?

    Keep the signal light lens clean and free of grease or debris to ensure visibility. Inspect wiring connections periodically for looseness or corrosion. Ensure proper voltage supply and replace the bulb if flickering occurs to maintain safe operation.

  • What are common issues with the Crown Steam PE-139 Signal Light?

    • Flickering or intermittent illumination due to loose wiring or unstable voltage.
    • Bulb burnout from prolonged use or power surges.
    • Moisture ingress causing internal short circuits or reduced brightness.
    • Loose socket connection leading to inconsistent performance.