Pitco P8905-03 Fryer Thermostat RX 3/8 X 5, Cap 36"
Specifications:
| Attribute | Details |
|---|---|
| [ Rx T'Stat] [ Temp 200-400 F] [ Bulb 3/8" X 5" ] | |
| [ Cap 36" ] [ Mount 11 ] [ Size 1/4" Mpt Stuff Box ] | |
| [ Dial # 22-1027, Black Knob W/ White Printed Numbers | |
| [ 2-1/4" Dia ] [Off- 400-200] [.187"] [Flat Down ] | |
| Gen Use Dial # 22-1006, Off-400-200, 4-Way Mount | |
| Anets Fryer 14Vfs, 18Eg Milivolt. Slg100 | |
| Imperial Fryer Series | If, Ihr, Ir. |
| Dean Fryer 11E, 11G, 14E, 14G, 32G, 714G, 1212G, 1212Gm, | |
| 1414Cms, 1414E, 1414G, 1818E, 1818G, 1824E, 1824G, 2020E, | |
| 2020G, 21414God, 2424E, 2424G, D-35, Llg, M-35, M-40Gm, Sr, | |
| Series | Sm. (Most Gas & Electric Fryers) |
| Pitco Fryer Sg |
Description
More Information:
- AMERICAN RANGE:AMRA50400||ANETS:60125401 ,P8905-03||BAKERS PRIDE:300232||DEAN:1175 ,1204 ,2557 ,807-3515 ,8073515||FAGOR:12189749||FRYMASTER:1175 ,1204 ,2557 ,807-3515 ,8073515 ,FM1175 ,FM1204 ,FM2557 ,FM807-3515 ,FM8073515||IMPERIAL:1175 ,1175-RS ,319 ,IMP1175 ,IMP319||JADE RANGE:8800000027||MARKET FORGE:93-0192||PITCO:60124501 ,60125401 ,P8905-03 ,PT60125401||ROYAL RANGE:3113||SIERRA RANGE:109-0084||SOUTHBEND:1182151 ,1199572 ,SOU1182151||TRI-STAR:300232 ,AS-300232 ,TRS300232||U-LINE:5300-40A ,KX299-36 ,RX1-36
Step1: Turn off power/gas and allow fryer to cool completely, drain oil safely.
Step2: Remove control panel and disconnect old thermostat wiring, labeling connections verify isolation switch.
Step3: Unscrew and extract faulty thermostat probe from fryer well.
Step4: Insert new probe, secure bracket, and reconnect wiring per labels check alignment.
Step5: Reassemble panel, restore power, test temperature calibration; ensure no leaks or overheating before restarting operation.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Pitco P8905-03 Thermostat?
Inspect the fryer capillary tube and bulb for kinks or oil buildup affecting sensing. Ensure secure mounting and clean probe area free from grease buildup and residue. Verify calibration regularly and replace the thermostat if erratic temperature readings occur.
-
What are common issues with the Pitco P8905-03 Thermostat?
- Inaccurate temperature control due to faulty sensor bulb.
- Capillary tube kinks or damage causing delayed response.
- Fryer thermostat stuck or unresponsive adjustment.
- Grease contamination affecting sensing accuracy.
- Loose connections leading to inconsistent heating.