Pitco P5045658 Fryer LP Gas Safety Valve with Bleed Gas Actuator 1/2" FPT 14"WC

SKU: P5045658 Brand: Availability:
In Stock
(0)

C$ 474.27 Price reduced from C$ 870.00
Save C$ 395.73


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Specifications:

Attribute Details
Robertshaw 700 Series Gas Safety Valve
[ Lp Gas ] [ Size 1/2" Fpt ] [ Lp Safety ][ Max 14"Wc ]
[Bleed Gas Actuator] [ Width 4"] [ Brand Rsw ]
1/4" Cct Pilot Out Only, W/Slotted Thermopile Magnet
1/2" X 3/8" Reducer Bushings, Model 7000 Bmsgor
Bleed Gas Ports 1/4" Cct, 240,000 Btu
Thermopile, H231, T-103, # 511122, Screw In Type, 7/16-27
Brass Pile Holding Nut, 3/8-38 Thread, For Magnet, 750Mv,
500Mv Under Load,
Pitco Fryer 12,14,14Bif,14R,14Ufm,18,18Bif,18Ufm,35C+,40C+,
45C+,7,Pm14,Pr14 18, 18S, P-18
Southbend Fryer Series 14, 18
Wolf Fryer Wtf-42, Ss-Wtf-42

Description

The Pitco P5045658 Fryer LP Gas Safety Valve is an essential safety part for propane gas applications. The valve of this type is 1/2” FPT and it has a bleed gas actuator which controls the flow of gas and prevents gas leakage. It works at maximum pressure of 14”WC that makes it appropriate to work at high temperatures. Advantages are increased safety, durability, and reliability when used under heavy loads and compatible with PR14 and PM14 fryers. It is essential for commercial kitchen to have this valve to for better performance and safety.

More Information:

  • DYNAMIC COOKING SYSTEMS:13298||GARLAND:1092701||HOBART:00-711356 ,11356 ,711356||PITCO:P5045644 ,P5045658||SOUTHBEND:1053995 ,1053996||VULCAN HART:00-711356 ,11356 ,711356

Step1: Turn off gas supply and disconnect power to ensure safe working conditions.

Step2: Allow the fryer to cool completely before accessing internal components.

Step3: Remove the old safety valve and disconnect gas lines and actuator connections.

Step4: Install the new valve, applying thread sealant to all gas fittings.

Step5: Reconnect actuator and gas lines securely, ensuring tight connections.

Step6: Restore gas and power, then check carefully for leaks and proper operation.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Pitco P5045658 Gas Safety Valve?

    Inspect the valve for proper operation and check for gas leaks. Keep it clean and ensure connections are secure. Routine maintenance supports accurate gas shutoff and secure fryer operation.

  • What are common issues with the Pitco P5045658 Gas Safety Valve?

    • Valve failing to shut off the gas flow.
    • Gas leakage from faulty seals.
    • Delayed valve response during operation.
    • Internal wear affecting performance.
    • Blockages restricting gas passage.
    • Inconsistent safety activation.