ATOSA 301040013 Orifice Hood #49 Propane Gas

SKU: 301040013 Brand: Availability:
In Stock
(0)

C$ 9.99


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Specifications:

Attribute Details
Burner Orifice #49
Imperial
Broiler Icb-4827, Icb-6027.
Series Gd (Glowing Devil).
Range Series Ihr.

Description

The ATOSA 301040013 Orifice Hood #49 is part of the propane gas control that is utilised in burner assembly. The orifice hood is installed at the point of entry of the gas and it offer precise restriction of the flows to enable stable operating conditions. Its purpose in the system is a essential aspect in ensuring a steady performance of the burner and regulated heat production. This orifice hood is usually used in commercial operations where propane systems need to have tight control of the gas in order to operate in a stable condition.

More Information:

  • APW WYOTT:2066849 ,AS-2066849||ATOSA:301040013||BAKERS PRIDE:2066849 ,BKPR3043A ,BKPR3043X ,R3043A ,R3043X||GARLAND:1020849 ,223242-49 ,G7266-49F ,GL1020849 ,GL223242-49 ,GLM8-49 ,M8-49||GLASS MAID:8-49||HOBART:00-719951-00049 ,19951-49 ,719951-00049 ,719951-49||IMPERIAL:1700-49 ,2064 ,IMP1700-49 ,IMP2064||JADE RANGE:46-213 ,460-213-000 ,460213000 ,4621300000||MAGIKITCH'N:29-08-00323A ,2908-0032300 ,MK29-08-00323A ,MK2908-0032300||SOUTHBEND:1006449 ,1008749 ,SOU1006449 ,SOU1008749||STAR MFG:2A-0032300||VULCAN HART:00-719951-00049 ,19951-49 ,719951-00049 ,719951-49 ,VH00-719951-00049 ,VH19951-49 ,VH719951-00049 ,VH719951-49

Step1: Turn off gas supply and disconnect power.

Step2: Allow equipment to cool completely.

Step3: Remove burner assembly cover using a proper tool.

Step4: Locate and unscrew the old orifice carefully.

Step5: Install the new orifice and tighten securely.

Step6: Reassemble burner components.

Step7: Restore gas and power, then check for leaks and proper flame.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the ATOSA 301040013 Burner Orifice?

    Clean the burner orifice regularly to prevent carbon buildup and clogging that can affect gas flow. Inspect for blockages, wear, or corrosion during regular service. Ensure proper alignment and secure fitting to maintain efficient combustion and better operation.

  • What are common issues with the ATOSA 301040013 Burner Orifice?

    • Clogging from grease or carbon buildup causing uneven flame.
    • Reduced gas flow leading to weak burner performance.
    • Corrosion or wear affecting combustion efficiency.
    • Misalignment resulting in improper ignition or flame instability.