Frymaster 8261756 Fryer Pump Motor W/Gasket Kit 1/3HP 1425/1725 RPM 208V 50/60Hz

SKU: 8261756 Brand: Availability:
In Stock
(0)

C$ 755.86 Price reduced from C$ 1,448.94
Save C$ 693.08


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Specifications:

Attribute Details
Pump Motor
1/3 Hp, 208V, 50/60 Hz, 3.7/2.9A, 1425/1725 RPM, 1 Phase
Frame = 48Yz, With Gasket
Frymaster 2836 W/O Float Switch, Bih152, Bih252, Bih352,
Bih452, Bih52, Bih552, Biph14, Biph252/255, Biph352/355,
Biph452/455, Biph52/55, Biph552, Bire14, Fh150, Fm345E,
Fm35, Fm45, Fm47, Fmh50, Fp128-136S, Fp128-236S, Fp228,
Fph150, Fph350Csd, Fph50, Fpph355Blcsd, Fpph355Csd, H14,
H17, H22, H50, H55, Jbih252, Mh152, Mh252, Mh352, Mh452,
Mh52, Mh552, Mj35, Mj45, Mj47, Mjh150, Mjh50, Mph14,
Mph152/155, Mph252/255, Mph352/355, Mph452/455, Mph52/55,
Mre14, Ph155Csd, Pmj35, Pro Series, Re14, Re17, Re22

Description

The Frymaster 8261756 Fryer Pump Motor With Gasket Kit 1/3-1425/1725-208-50/60 is a replacement oil circulating assembly that fits compatible commercial fryers. It pumps the oil in the fryer to flow through filtration and heating loops, which maintain a constant flow and temperature of the oil as it flows. The gasket that comes along gives an proper seal between the pump and the housing to avoid leakages. This motor and gasket assembly is installed in the lower service compartment of the fryer and is part of the oil handling system of the fryer and is normally used in restaurants and kitchen settings.

More Information:

  • DEAN:826-1756||FRYMASTER:807-6321 ,8076321 ,826-1756 ,8261756 ,FM826-1756 ,FM8261756

Step1: Disconnect electrical power and allow the unit to cool completely.

Step2: Shut off and secure the oil system to prevent spills or pressure release.

Step3: Remove the access panel to reach the pump motor assembly.

Step4: Disconnect electrical wiring and label connections for correct reassembly.

Step5: Unbolt and carefully remove the old pump motor and gasket assembly.

Step6: Position the new motor with gasket aligned to the mounting surface.

Step7: Secure mounting bolts evenly, reconnect wiring, and ensure all seals are tight.

Step8: Restore power, check for leaks, and test oil circulation and pump operation.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Frymaster 8261756 Pump Motor With Gasket?

    Inspect and clean the pump motor regularly to prevent grease buildup and debris around the gasket. Ensure electrical connections remain tight and free from corrosion. Lubricate moving components if specified by manufacturer guidelines. Always disconnect power before servicing.

  • What are common issues with the Frymaster 8261756 Pump Motor With Gasket?

    • Overheating due to motor strain or blocked airflow.
    • Pump failure from worn seals or gasket leakage.
    • Irregular speed causing inconsistent fluid circulation.
    • Electrical faults leading to startup failure or shutdown.