Johnson Controls H91DG-2 Natural/LP Gas Valve W/ 1/4" tab terminal 1/2" FPT

SKU: H91DG-2 Brand: Availability:
In Stock
(0)

C$ 294.06 Price reduced from C$ 396.07
Save C$ 102.01


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Specifications:

Attribute Details
Type Gas Solenoid Shutoff Valve
Voltage 25 V
Gas Type Natural Gas/Liquid Propane
Connection 1/2 in. FPT
Capacity 240000 BTU
Operation Normally Closed
Terminal Type 1/4 in. Tab Terminals

Description

The Johnson Controls H91DG-2 Natural/LP Gas Valve functions as a reliable gas flow controller for gas-powered appliances which can be used in ovens, grills and ranges. The partincludes 1/2" FPT fittings for inlet and outlet while using a 1/4" tab terminal and works at 25V with NC mode activation. This valve reaches its maximum output at 240,000 BTU which makes it suitable for efficient appliances. The gas valve works with Imperial Ovens together with Lang/Star Grills and additional appliance models. The gas valve enables secure and dependable operation which enhances both appliance durability and energy efficiency.

More Information:

  • IMPERIAL:33885 ,36240||JOHNSON CONTROLS:H91DG-2||LANG:2V-80501-03 ,2V-80502-03 ,2V80502-03 ,80501-03 ,80502-03 ,LG2V-80502-03 ,LG2V80502-03 ,LG80502-03||STAR MFG:2V-80501-03 ,2V-80502-03 ,2V-Z5104 ,2V80502-03 ,80502-03||STERO:STA2V-80502-03 ,STA2V80502-03 ,STA80502-03

Step 1: Turn off the gas supply and disconnect electrical power before installation.

Step 2: Confirm the valve matches the gas type (Natural Gas or LP) and voltage requirements.

Step 3: Install the valve in the correct flow direction using approved pipe sealant on threaded connections.

Step 4: Secure all electrical wiring according to the equipment wiring diagram.

Step 5: Restore power and gas, then check for leaks with a soap solution and verify proper valve operation.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Johnson Controls H91DG-2 Gas Valve?

    Regularly inspect the gas valve for leaks, corrosion, or blockages. Ensure connections are secure and clean any debris around the valve. Test the valve operation periodically for proper gas flow. Always turn off the gas supply before performing maintenance.

  • What are common issues with the Johnson Controls H91DG-2 Gas Valve?

    • Valve failing to open or close properly.
    • Gas leaks or weak flow.
    • Corrosion or buildup inside the valve.
    • Faulty electrical connections affecting operation.
    • Intermittent or inconsistent gas delivery.