Step1: Disconnect the appliance from power and allow the unit to cool completely.
Step2: Remove the access panel to locate the existing hi-limit thermostat.
Step3: Disconnect the wires from the old hi-limit and remove the mounting screws and bracket.
Step4: Position the new hi-limit with the bracket in the same location and secure it with screws.
Step5: Reconnect the electrical wires to the matching terminals.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Adcraft FW-1200WS Hi Limit With Bracket?
Inspect the hi-limit and bracket regularly for dirt, corrosion, or loose connections. Clean contacts with a soft cloth and ensure secure mounting. Proper maintenance ensures accurate temperature control and prevents overheating hazards. Avoid using harsh chemicals that could damage components.
-
What are common issues with the Adcraft FW-1200WS Hi Limit With Bracket?
- Failure to trigger at the correct temperature.
- Loose or damaged mounting bracket.
- Corroded or dirty electrical contacts.
- Intermittent operation or false trips.