Lang 41100-07 Oven Flame Sensor 1-1/4" Probe 1/4" Tab Ternial

SKU: 41100-07 Brand: Availability:
In Stock
(0)

C$ 32.73 Price reduced from C$ 47.99
Save C$ 15.26


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Specifications:

Attribute Details
Flame Sensor, 1-1/4" Probe,
1/4" Tab Ternial 90 Degree.
Fits Pilot Burners # 51-1192 & 51-1193
Anets
Blodgett Dfg, 100, 200, 300, Cos-5, Bcs-8G, Cos-20G
Mg32S, Mg3270, Mt2136G, Mt3255, My3855G, Mt3870.
Falcon
Lang Oven Gcc0-(A,Ap,Ap-Xd), Gcco-C
(Beg With S/N V90069 & X To X90068),
Gcco-(C-Xd,Prsn-Pk,S,Sii,Sii-Xd,T,T-Xd).

Description

The Lang 41100-07 Oven Flame Sensor is used to identify flame in an oven system to assist and stabilize in a commercial oven. This 1-1/4 inch probe with 1/4 inch tab terminal component of the burner control system, which makes it possible to closely monitor ignition and combustion under optimum conditions. It is installed in the specific burner area and is an essential component in ensuring uniform heating. The flame sensor is often used in commercial kitchen ovens to maintain a controlled burner activity and helps to maintain consistent oven operation during the usual cooking cycles to the entire system.

More Information:

  • ANETS:P8905-33||BLODGETT:18256 ,BL18256||FALCON:536003328||HENNY PENNY:76978||JOHNSON CONTROLS:Y75AA-3 ,Y75AA3||LANG:2E-41100-07 ,41100-07||PITCO:P8905-33||STAR MFG:2E-41100-07 ,2E41100-07||STERO:STA2E-41100-07 ,STA2E41100-07

Step1: Turn off gas and electrical power to the unit before servicing.

Step2: Allow burner area to cool completely.

Step3: Remove burner access panel to expose flame sensor placed.

Step4: Disconnect wiring from existing flame sensor terminal.

Step5: Remove faulty sensor from mounting bracket.

Step6: Install new probe flame sensor in correct position near flame path.

Step7: Reconnect tab terminal securely and ensure proper grounding.

Step8: Restore power and gas, then check stable flame detection during ignition cycle.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Lang 41100-07 Flame Sensor?

    Clean the flame sensor probe regularly to remove carbon buildup and oxidation that can block flame detection. Inspect the wiring terminal for looseness or corrosion. Ensure proper alignment within the burner flame path. Always shut off power and gas before servicing to maintain safety.

  • What are common issues with the Lang 41100-07 Flame Sensor?

    • Failure to detect flame causing ignition lockout.
    • Carbon buildup leading to weak or inconsistent signal.
    • Loose or corroded terminal connection.
    • Misalignment with burner flame reducing sensing accuracy.