Turbo Air M607000100 Evaporator Coil

SKU: M607000100 Brand: Availability:
In Stock
(0)

C$ 489.76 Price reduced from C$ 665.56
Save C$ 175.80


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Description

The Turbo Air M607000100 Evaporator Coil is a refrigeration component that is used to absorb heat in interior of the commercial appliance. It works by enabling the refrigerant to circulate through the coil where it evaporates and cools down the surrounding air. It is fitted within the cabinet and it is used together with the fan system to ensure a constant flow of air and even distribution of temperature. It is a key component of the refrigeration cycle and its operation assists in efficient operation and in maintaining stored products by stabilizing temperatures in refrigeration application.

More Information:

Manufacturer Name: Turbo Air
Product Number: M607000100
OEM Part Number: M607000100
Product Description: Evaporator Coil
Similar Models:NONE
Dimensions:
Length:29in/73.66cm
Width:7in/17.78cm
Height:3in/7.62cm
Weight:3.9lbs/1769.01g

Choose the best Commercial kitchen & Restaurant equipment parts and supplies from {{config path='general/store_information/name'}}!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at {{config path='general/store_information/phone'}} or {{config path='trans_email/ident_support/email'}}

Step1: Disconnect main power supply and isolate refrigeration system wear gloves and safety goggles to prevent injury.

Step2: Recover refrigerant using certified recovery machine following environmental regulations.

Step3: Remove access panel carefully and disconnect the old evaporator coil from mounting brackets.

Step4: Install Evaporator Coil, secure fittings tightly and ensure proper alignment.

Step5: Reconnect refrigerant lines and electrical connections ensuring all seals are tight.

Step6: Perform vacuum leak test, then restore power and check cooling performance for safe operation.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Turbo Air M607000100 Evaporator Coil?

    Regularly inspect the evaporator coil for dust, dirt, and frost buildup, and clean it using a soft brush or proper coil cleaner. Ensure proper airflow by keeping surrounding areas unobstructed. Check for leaks or corrosion periodically. Always disconnect power before servicing to ensure safety.

  • What are common issues with the Turbo Air M607000100 Evaporator Coil?

    • Ice buildup reducing cooling efficiency.
    • Refrigerant leaks causing poor performance.
    • Corrosion or rust on coil surfaces.
    • Restricted airflow due to dirt accumulation.
    • Uneven cooling or temperature fluctuations.