APW 2068500 Char-Broiler Burner Valve Push-to-Turn 1/8" MPT X 3/8"-27

SKU: 2068500 Brand: Availability:
Out of Stock
(0)

C$ 69.46 Price reduced from C$ 79.62
Save C$ 10.16


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Description

The APW 2068500 Burner Push-to-Turn 1/8 MPT X 3/8-27 is a designed product to be used in commercial charbroilers. It controls the quantity of gas entering the burner, and therefore, the ignition is produced accurately, and the intensity of the flame can be adjusted using its push-to-turn system. It is usually fitted to the front or side panel of the broiler and is connected directly to the gas supply and communicates with the burner assembly so as to have controlled operation.

More Information:

Manufacturer Name: APW
Product Number: 2068500
OEM Part Number: 2068500
Product Description: [ 1/8" Mpt X 3/8"-27 ] [ Rotation Off/On];Push To Turn;American Permanent Ware Griddle Ggm, Ggt Ghp-4H
Similar Models:2068200 - APW
Dimensions:
Length:3in/7.62cm
Width:1.25in/3.18cm
Height:0.75in/1.9cm
Weight:0.3lbs/136.08g

Choose the best Commercial kitchen & Restaurant equipment parts and supplies from {{config path='general/store_information/name'}}!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at {{config path='general/store_information/phone'}} or {{config path='trans_email/ident_support/email'}}

  • APW WYOTT:2068200 ,2068500 ,AS-2068500

Step1: Turn off the gas supply and disconnect the appliance from power.

Step2: Remove the old burner valve by unscrewing it from the gas line.

Step3: Inspect the connection for debris or damage before installing the new valve.

Step4: Screw in the valve by hand, then tighten with a wrench.

Step5: Ensure the push-to-turn mechanism operates smoothly.

Step6: Reconnect the gas supply and check for leaks using a soapy water test.

Step7: Restore power and test burner operation.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the APW 2068500 Push-to-Turn Burner Valve?

    Inspect the valve regularly for grease, debris, or corrosion, and clean it with a dry cloth. Check threaded connections for leaks using soapy water. Verify the push-to-turn action moves freely. Replace worn seals promptly to maintain secure, accurate gas control.

  • What are common issues with the APW 2068500 Push-to-Turn Burner Valve?

    • Sticking or hard-to-turn valve operation
    • Gas leaks from worn seals
    • Inconsistent flame or burner ignition
    • Valve handle damage or loosening over time.