Imperial 2103 Range 3-Ring Cast Iron Burner Assembly W/pipe Nipples Air Shutters 12" DIA
Specifications:
| Attribute | Details |
|---|---|
| 3 Ring Cast Iron Burner Assy | |
| 12" Dia, 90,000 Btu | |
| Now Complete W/Pipe Nipples. | |
| Air Shutters Are Both Same Size, | |
| Single Air Shutter With 2 Windows, 2.848" Id, .467" Hole. | |
| For Air Shutter Only Use # 26-2729 | |
| Dynamic Cooking Systems | |
| Imperial Range Ispa, Tempura |
Description
More Information:
- DYNAMIC COOKING SYSTEMS:12027 ,12028||IMPERIAL:15000 ,15003 ,15004 ,2103
Step1: Turn off gas supply and allow the unit to cool completely before servicing.
Step2: Remove grates and lift out the existing burner assembly from the range top.
Step3: Disconnect the gas feed/orifice and any mounting hardware securing the burner.
Step4: Position the new burner assembly, aligning it with the gas inlet and supports.
Step5: Secure with original hardware and reconnect the gas line tightly.
Step6: Restore gas supply, check for leaks, and test for a stable, even flame.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Imperial 2103 Burner Assembly?
Clean Range burner ports and air shutters regularly to prevent clogging and uneven flame. Inspect pipe nipples and connections for gas leaks or corrosion. Ensure proper alignment for safe combustion and efficient heat output.
-
How do I install the Imperial 2103 Burner Assembly?
- Turn off gas and power to the appliance and allow components to cool.
- Remove the existing burner by detaching mounting screws and disconnecting the gas feed.
- Position the Imperial 2103 burner in place and secure it with the original hardware.
- Reconnect the gas line or orifice to the burner inlet.
- Restore power and gas, then test for proper ignition and a stable, even flame.
-
What are common issues with the Imperial 2103 Burner Assembly?
Common issues include uneven flame due to blocked burner ports, delayed ignition from residue buildup, and wear on mounting points causing misalignment. Regular cleaning and proper seating help prevent most failures.
-
What are the operating limitations for the Imperial 2103 Burner Assembly?
Burner assemblies of this type typically operate within standard commercial gas appliance ranges, supporting natural gas or LP with output commonly between 20,000–40,000 BTU depending on the unit.
-
What are common issues with theImperial 2103 Burner Assembly?
- Uneven flame distribution due to clogged burner ports.
- Gas leakage from worn pipe nipples or fittings.
- Poor ignition caused by dirty air shutters or misalignment.
- Overheating or warped cast iron burner assembly under heavy use