Accutemp AT2E-4717-1 Rev A G2 Gas Griddle Flame Sensor

SKU: AT2E-4717-1 Brand: Availability:
In Stock
(0)

C$ 27.60


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Description

The Accutemp AT2E-4717-1 Rev A G2 Flame Sensor is a fine-tuning element that is installed in commercial griddle to identify the existence of a flame. It is mounted directly into the burner system of the griddle and is fed back to the control module to allow it to operate. Flame activity is monitored to stop the flow of gases in the absence of ignition to ensure standards and performance in cooking. This sensor plays a vital role in the correct operation of professional kitchen griddle, which allows maintaining a stable heat level and operating under the conditions of high activity in food service settings.

More Information:

Manufacturer Name: Accutemp
Product Number: AT2E-4717-1
OEM Part Number: AT2E-4717-1
Product Description: Flame Sensor, Rev A G2 Gas Griddle
Similar Models:AT2E47171 - Accutemp
Dimensions:
Length:4in/10.16cm
Width:0.5in/1.27cm
Height:0.25in/0.64cm
Weight:0.37lbs/167.83g

Choose the best Commercial kitchen & Restaurant equipment parts and supplies from {{config path='general/store_information/name'}}!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at {{config path='general/store_information/phone'}} or {{config path='trans_email/ident_support/email'}}

  • ACCUTEMP:AT2E-4717-1 ,AT2E47171

Step1: Turn off gas supply and disconnect electrical power before servicing the griddle.

Step2: Remove the front access panel to reach the burner and existing flame sensor assembly.

Step3: Disconnect the flame sense wire and unscrew the old sensor from its mounting bracket.

Step4: Position the new sensor in the same orientation near the burner flame path.

Step5: Secure it tightly with screws and reconnect the flame sense wire to the control module.

Step6: Restore power and gas, then test ignition to confirm stable flame detection and proper operation.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Accutemp AT2E-4717-1 Flame Sensor?

    Clean the griddle flame sensor regularly to remove carbon buildup that can affect flame detection. Inspect wiring connections for looseness or corrosion. Proper maintenance ensures accurate ignition monitoring and prevents unsafe gas flow issues in the griddle system.

  • What are common issues with the Accutemp AT2E-4717-1 Flame Sensor?

    • Weak flame detection from carbon buildup.
    • Faulty ignition signal or intermittent readings.
    • Loose or damaged wiring connections.
    • Sensor corrosion from heat and moisture exposure.