Anets P8905-02 Fryer High Limit Thermostat 450°F LCC
Specifications:
| Attribute | Details |
|---|---|
| [ Type - Lccm W/Auto Reset ] [ Temp 450 Fixed ] | |
| [ Bulb 5/16" X 3-1/2" Nickel ] [ Cap 36" ] | |
| [ Size 3/8" Stuff Box Nickel ] [ Brkt 1 ] | |
| American Range Fryer | |
| Anets Fryer 14Uf(S) | |
| Imperial Fryer Series | If, Ihr, Ir. |
| Tri-Star Fryer |
Description
More Information:
- AMERICAN RANGE:A10007 ,AMRA10007||ANETS:P8905-02 ,P8906-07||APW WYOTT:13016-27||IMPERIAL:1177 ,IMP1177||JADE RANGE:8800000023||MARKET FORGE:93-0194||PITCO:P8905-02 ,P8906-07||ROYAL RANGE:3112||SIERRA RANGE:109-0085||TRI-STAR:300228 ,AS-300228 ,TRS300228||U-LINE:5225-12D ,LCCM080360000
Step1: Power off equipment and isolate gas/electric supply.
Step2: Remove old thermostat and note wiring positions.
Step3: Mount new thermostat securely at capillary location.
Step4: Reconnect wires per schematic; ensure tight insulation.
Step5: Restore power and test auto reset at safe temp.
Step6: check calibration and check for leaks/overheat safety.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Anets P8905-02 Safety Thermostat?
Inspect thermostat calibration and wiring connections regularly to ensure accurate temperature control and safe operation. Clean contacts and housing to prevent debris buildup affecting response and triggering errors.
-
What are common issues with the Anets P8905-02 Safety Thermostat?
- Inaccurate temperature sensing or drift causing improper heat regulation.
- Electrical contact wear or corrosion causing intermittent operation.
- Relay sticking or failure preventing proper heating control.
- Overheating shutdown triggers at incorrect thresholds.