Frymaster 8070918 Spark Ignition Module 11-Seconds 3 AMP 25V

SKU: 8070918 Brand: Availability:
Out of Stock
(0)

C$341.44 Price reduced from C$484.06
Save C$142.62


Have a Question? +1 (866) 963-0907 / (630) 326-8602

Specifications:

Attribute Details
25V Direct Spark Ignition Module,
11 Sec Lockout, 5Ea 1/4" Tab Terminals, 3 Amp Fuse (Ap#
381050),
Rajah Spark Term & 1/4" Spark Term On Top.
4" X 5-1/16"
For Use With A Flame Sensor And Ignitor.
Before 1998 Use Spark Cable 27", # 38-1334
1998 And After Use 20" Spark Cable, # 38-1363
Frymaster
Fryer Fh250, G18Fb, G24Fb, Gl18Fb,
Gl24Fb, He, Mach52, Mjh50.

Description

The Frymaster 8070918 Direct Spark Ignition Module Lockout 5EA 1/4" Tab Terminals operates by receiving a call-for-heat signal and generating a high voltage to ignite the gas-air mixture at the burner during the startup sequence. It operates through an internal control circuit that activates the spark electrode while also coordinating gas valve opening, and it monitor flame presence to confirm ignition. If flame is not detected within the preset 11-second time frame, the module triggers a lockout to stop operation until reset.

More Information:

  • DEAN:807-0918||FRYMASTER:807-0918 ,8070918 ,FM807-0918 ,FM8070918||GILES:22975||LEGION:431138

Step1: Disconnect fryer from power and shut off the gas supply before starting.

Step2: Access the control panel and locate the existing ignition module.

Step3: Label and remove the wires from the old module’s terminals.

Step4: Remove mounting screws and take out the faulty module.

Step5: Mount the new module securely in the same position.

Step6: Reconnect wires to the matching tab terminals.

Step7: Restore power and gas, then test ignition for proper operation.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Frymaster 8070918 Direct Spark Ignition Module?

    Inspect the ignition module’s tab terminals for tight, clean connections and signs of heat damage. Keep the control area free from grease and moisture that can affect electrical performance. Verify secure mounting and proper airflow to prevent overheating. Disconnect power before servicing to avoid electrical shock.

  • What are common issues with the Frymaster 8070918 Direct Spark Ignition Module?

    • Failure to generate a spark during startup.
    • Intermittent ignition or delayed burner lighting.
    • Loose or damaged wiring connections.
    • Ignition lockout caused by faulty grounding.