Dean 807-0280 Hi-Limit Adapter W/18" Wire Leads & 2 Screw Term Lugs
Specifications:
| Attribute | Details |
|---|---|
| Hi-Limit Adaptor, 18" Wire Leads W/ 2 Screw Term Lugs | |
| Anets Model? | |
| Cecilware Fryer Fm28, Fm28A, Gf8, Gf10, Gf16, Gf16A, Gf28, | |
| Gf28A. | |
| Frymaster Fryer Mac(50,51,150,151,250,251,350,351), Mj41, | |
| Mj41E, Mj45E, Mjcf, Mjcfe, All Computer Magic Ii & Iii. | |
| Garland Fryer | |
| Pitco Fryer All Gas Fryers W/Lch High Limit. | |
| Rethermalizer Rtg14, Rtg14 (Taco Bell). | |
| Southbend Fryer Model? | |
| Vulcan Fryer 7891E, 7891G, 7892E, 7892G,Hf91E, | |
| Hf91G, Hf92E, Hf92G. | |
| Wolf Model Wtf-35, Wtf-42 |
Description
More Information:
- ANETS:P8903-51||CECILWARE:GML115A ,GML115F ,L113A ,L113F ,L115A ,L115F||COMSTOCK CASTLE:HWL||DEAN:807-0280 ,8070280||FRYMASTER:807-0280 ,8070280 ,FM807-0280 ,FM8070280||GARLAND:1092702 ,GL1092702||GRINDMASTER:L113A ,L113F||HOBART:00-410838-000G1 ,00-721042-00001 ,110838-G1 ,11358 ,21042-1 ,410838-000G1 ,410838-G1 ,711358 ,721042-00001 ,721042-1||METAL MASTERS:310313||PITCO:B6779850 ,P5047526 ,P6071805 ,P8903-51 ,P9087601 ,PTB6779850 ,PTP6071805 ,PTP9087601||SOUTHBEND:1054400 ,1080299 ,1163416 ,1163417 ,SOU1054400 ,SOU1080299 ,SOU1163416 ,SOU1163417||U-LINE:10-258||VULCAN HART:00-410838-000G1 ,00-721042-00001 ,110838-G1 ,110838G1 ,11358 ,21042-1 ,410838-000G1 ,410838-G1 ,410838G1 ,711358 ,721042-00001 ,721042-1 ,VH110838G1 ,VH410838G1
Step1: Turn off power and gas supply to the fryer before servicing.
Step2: Remove the access panel and locate the existing hi-limit connection.
Step3: Disconnect the old adapter and inspect the wiring terminals.
Step4: Install the Hi-Limit Adapter in the correct position.
Step5: Connect the wire leads to the matching terminals.
Step6: Secure the screw terminal lugs firmly.
Step7: Restore power and gas supply, then test fryer safety controls for proper operation.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Dean 807-0280 Hi-Limit Adapter?
Inspect the hi-limit adapter regularly for secure wire connections and signs of overheating or insulation wear. Tighten screw terminals to prevent electrical resistance buildup. Keep the area clean and dry to avoid corrosion. Proper maintenance ensures better temperature cutoff performance and reliable appliance protection.
-
What are common issues with the Dean 807-0280 Hi-Limit Adapter?
- Loose or burnt wire connections.
- Intermittent hi-limit tripping.
- Damaged insulation on leads.
- Corrosion at screw terminals.
- Failure to trip at correct temperature.
- Electrical shorts or open circuit faults.
- Overheating due to poor contact.