| Manufacturer Name: Manitowoc Product Number: 7627813 OEM Part Number: 7627813 Product Description: Ice Thickness Probe, 4" 3-1/4" Ovverall;Manitowoc Ice Machine Series: Q, Except Q130,Q210, Q270.;Q Series Ending In P (Prison) & C, Dual C Units.;Series: B, J. Similar Models:76-2781-3 - Manitowoc Dimensions: Length:5in/12.7cm Width:4.5in/11.43cm Height:1in/2.54cm Weight:0.11lbs/49.9g |
Choose the best Commercial kitchen & Restaurant equipment parts and supplies from {{config path='general/store_information/name'}}!
Same Day Shipping
Best Quality And Best Price
Wide Range of Inventory
Best Customer Service
Have More Questions or Need Help to Place The Order?
Reach us at {{config path='general/store_information/phone'}} or {{config path='trans_email/ident_support/email'}}
- MANITOWOC:76-2781-3 ,7627813 ,MAN76-2781-3 ,MAN7627813
Step1: Turn off and unplug the unit to prevent electrical hazards.
Step2: Access the probe area by removing the front or top panel.
Step3: Detach the old probe from its bracket and unplug connections.
Step4: Position the replacement probe correctly against the evaporator.
Step5: Secure it firmly and reconnect all electrical leads.
Step6: Reassemble panels, power on, and check ice formation consistency.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Manitowoc 7627813 Ice Thickness Probe?
Regularly inspect the probe tip for mineral buildup or debris that could affect readings. Ensure electrical connections are secure and the probe is properly seated. Test measurement accuracy periodically and clean gently with a non-abrasive solution.
-
What are common issues with the Manitowoc 7627813 Ice Thickness Probe?
- Inaccurate ice thickness readings.
- Probe failing to detect ice consistently.
- Intermittent electrical signal.
- Loose mounting is affecting measurements.