Pitco 60138801 Fryer Gas Thermostat 200°F- 450°F
Specifications:
| Attribute | Details |
|---|---|
| Gs Thermostat, 200° - 450°F, Bulb 4" Long 3/8" Dia. | |
| Cap Tube Length = 30". Gas In/Out 1/2",With 1/2" Npt X 3/8" | |
| Cct 90° Elbow. | |
| Fits Magikitchn Models~ | |
| Fg-Mkg48-Stl, Mkg-36-E, Mkg24, Mkg36, Mkg48, Mkg60, Mkg72 |
Description
More Information:
- MAGIKITCH'N:2T-60138801 ,60138801||PITCO:60138801||STAR MFG:2T-60138801
Step1: Turn off gas supply and disconnect power to the fryer.
Step2: Allow the unit to cool completely before starting.
Step3: Remove control panel and locate the existing thermostat.
Step4: Disconnect capillary tube and wiring carefully.
Step5: Install the new thermostat, securing the bulb in position.
Step6: Reconnect wiring and reassemble the panel.
Step7: Restore gas and power, then test temperature operation safely.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Pitco 60138801 Thermostat?
Check the thermostat periodically for buildup on the sensor bulb or capillary line — wipe the exterior gently to clear grease or debris. Ensure the dial and control knob remain functional and that bulb/capillary are properly secured and not kinked.
-
How do I install the Pitco 60138801 Thermostat?
- Shut off gas supply and allow fryer/equipment to cool.
- Remove the old thermostat — detach the capillary bulb and unscrew housing.
- Install the new thermostat: mount body in control panel, route the capillary tube without sharp bends, and position the 4-inch sensing bulb in the correct oil or chamber location.
- Reconnect gas valve linkage or wiring per original configuration.
- Restore gas supply, light pilot/burner, then test by adjusting the thermostat and verifying temperature response between 200 °F and 450 °F.
-
What are common issues with the Pitco 60138801 Thermostat?
Common problems include inaccurate temperature regulation if the sensing bulb is improperly placed or the capillary gets kinked. Another issue: thermostat failing to control gas flame properly — often due to wear in internal components or faulty bulb sensing.
-
What are the operating limitations for the Pitco 60138801 Thermostat?
The thermostat is rated for gas operation over a temperature range of 200 °F to 450 °F. Its capillary tube is 30" long with a 4" sensing bulb.
-
What maintenance is required for the Pitco 60138801 Gas Thermostat?
Check the fryer gas thermostat for accurate response during temperature adjustments. Keep surrounding components free from oil residue. Inspect sensing elements for placement. Clear operation allows consistent heat control in the fryer.
-
What are common issues with the Pitco 60138801 Gas Thermostat?
- Temperature not matching set level.
- Delayed burner response.
- Inconsistent heating during frying.
- Thermostat failing to regulate gas flow.