Specifications:

Attribute Details
Defrost Thermostat, 2 Wire, Surface Mount,
Open 75 F, Close 40 F, 120/240V, 25 Amp Max, Spst
Bohn, Larkin, Chandler,
Climate Control 5708L, 4752C

Description

The Heatcraft 5708L Defrost Thermostat is a key component that regulates temperature performance in refrigeration systems. This thermostat operates between 75°F and 40°F to run efficient defrost cycles which stop ice formation that affects system performance. This thermostat features a surface mount design which enables simple installation across different applications thus making it suitable for improve and residential refrigeration units, with a maximum capacity of 25 amps and 120/240V voltage. The thermostat delivers exceptional benefits to temperature-controlled environments because it provides precise management and ensures reliable operation alongside energy efficiency.

More Information:

  • BOHN:4208 ,5708L||HEATCRAFT:5708L ,L5708 ,SL5708||KAIRAK:324-29036-00||NORLAKE:078832||TRAULSEN:324-29036-00

Step1: Turn off the power to the appliance unit.

Step2: Locate the old defrost thermostat on the evaporator coil.

Step3: Disconnect wiring carefully.

Step4: Remove the old thermostat from its clip or bracket.

Step5: Inspect coil area for damage or ice buildup.

Step6: Install the new thermostat in the same position.

Step7: Reconnect wires securely.

Step8: Ensure the sensor is in full contact with the coil.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Heatcraft 5708L Defrost Thermostat?

    Regularly inspect the thermostat for loose connections or corrosion. Clean any dust or debris from surrounding areas and ensure proper mounting. Proper maintenance ensures accurate defrost cycles, prevents system inefficiency, and reduces the risk of frost buildup.

  • What are the common issues with the Heatcraft 5708L Defrost Thermostat?

    • Failure to initiate defrost cycles.
    • Inaccurate temperature sensing.
    • Loose or corroded electrical connections.
    • Intermittent operation causing frost accumulation.