- GARLAND:4530025 ,4531250 ,GL4530025 ,GL4531250
Step1: Turn off gas and electrical power to oven; verify no voltage.
Step2: Remove access panel and disconnect old ignition module wiring, labeling each connector.
Step3: Mount new module securely in same position using screws.
Step4: Reconnect wiring per labels, ensuring tight fit and proper grounding.
Step5: Restore power and test ignition cycle for secure flame operation; avoid gas leaks.