Vulcan Hart 412788-00048 Thermocouple 48''
Specifications:
| Attribute | Details |
|---|---|
| 1900 Series Heavy Duty Thermocouple 48" Long.20-30 Mv | |
| Coaxial Thermocouple Threads = 11/32"-32 | |
| Market Forge Skillet Where Applicable | |
| Southbend Hdg-(36, 36M, 36Re, 48, 48M, 48Re, 60, 60M, 60Re, | |
| 72, 72M, 72Re) | |
| Vulcan Hart Heavy Duty Range/Oven Gh3/72, Gh3/72C, Gh3/72S, | |
| Gh30, Gh30C, | |
| Gh45, Gh45/72, Gh56, Gh56S, Gh6, Gh60, Gh60/45, Gh60/72, | |
| Gh6045C, Gh60T, Gh60T/45, Gh60T/72, Gh6C, Gh6S, Gh6T45C, | |
| Gh72, Gh72/45, Ghm3/72, Ghm30, Ghm30C, Ghm45, Ghm45/72, | |
| Ghm56, Ghm6, Ghm60, Ghm60/45, Ghm60/72, Ghm60T, Ghm60T/45, | |
| Ghm60T/72, Ghm72, Ghm72/45 |
Description
More Information:
- HOBART:00-412788-00002 ,00-412788-00004 ,00-906955-00048 ,412788-00002 ,412788-00004 ,412788-2 ,412788-4 ,906955-00048 ,906955-48 ,HOB00-412788-00002 ,HOB00-412788-00004 ,HOB00-906955-00048 ,HOB412788-00002 ,HOB412788-00004 ,HOB412788-2 ,HOB412788-4 ,HOB906955-00048 ,HOB906955-48||MARKET FORGE:-10-4758 ,10-4758 ,MAR10-4758||SOUTHBEND:-1182565 ,1182565 ,SOU1182565||U-LINE:1900-048||VULCAN HART:-00-412788-00002 ,-00-412788-00004 ,-00-906955-00048 ,00-412788-00002 ,00-412788-00004 ,00-412788-00048 ,00-906955-00048 ,412788-00002 ,412788-00004 ,412788-00048 ,412788-2 ,412788-4 ,412788-48 ,906955-00048 ,906955-48 ,VH00-412788-00002 ,VH00-412788-00004 ,VH00-412788-00048 ,VH412788-00002 ,VH412788-00004 ,VH412788-00048 ,VH412788-2 ,VH412788-4 ,VH412788-48 ,VH906955-00048
Step1: Turn off gas/electric supply and allow equipment to cool before replacement.
Step2: Remove access panel and disconnect old thermocouple from control valve.
Step3: Position new thermocouple in pilot assembly, ensuring proper flame contact and alignment.
Step4: Secure connections to gas valve, tighten fittings without over-torquing.
Step5: Restore power, relight pilot, and test for stable millivolt output; check for leaks.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Vulcan Hart 412788-00048 Thermocouple?
Keep the thermocouple probe clean and free from carbon deposits to ensure accurate flame sensing. Verify the pilot flame properly envelops the sensor for consistent signal output. Inspect wiring and connections for tightness and stability during operation.
-
What are the common issues with the Vulcan Hart 412788-00048 Thermocouple?
- Weak signal output is causing pilot flame dropout.
- Improper flame contact leading to inconsistent gas control.
- Corroded terminals reduce electrical continuity.
- Carbon buildup affecting sensing accuracy and responsiveness.