Hobart 404193-1 Range Pilot Valve 1/8" MPT X 1/4" CCT
Specifications:
| Attribute | Details |
|---|---|
| Pilot Adjustment Valve[ 1/8" Mpt X 1/4" Cct ] | |
| Angle - 90 Degree. | |
| American Permanent Ware Broiler Gcb, Gcrb | |
| Griddle Ggm, Ggt | |
| Garland Most Models | |
| Jade Grill Series | Jggt, Jgm, Jgt. |
| Hotplate Series | Jhp, Jhpe. |
| Range Series | Jsp, Jsr, Jtrh. |
| Star Griddle | |
| Vulcan Broiler 100L-77R, Salamanders. | |
| Oven Series | 7000, 7800, Gh, Ghm, Ghx. |
Description
More Information:
- APW WYOTT:2068001 ,AS-2068001||GARLAND:1086596 ,G03674-1 ,G03674-3 ,GLG03674-1||HOBART:00-404193-00001 ,104193-1 ,1355 ,404193-00001 ,404193-1 ,801355||JADE RANGE:44-128 ,440-128-000 ,440128000 ,4412800000 ,4412800200||MONTAGUE:01000-6 ,1000-6||STAR MFG:2V-6671 ,2V6671 ,6671||STERO:STA2V-6671 ,STA2V6671 ,STA6671||VULCAN HART:00-404193-00001 ,104193-1 ,1355 ,404193-00001 ,404193-1 ,801355 ,VH104193-1 ,VH1355 ,VH404193-1 ,VH801355
Step1: Turn off gas/power and allow system to cool; relieve pressure.
Step2: Remove old pilot valve and clean connections.
Step3: Apply approved thread sealant and install new valve securely.
Step4: Tighten fittings to specification, avoiding over-torque.
Step5: Restore supply, check for leaks with soap solution, inspect seals, and test ignition safely.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Hobart 404193-1 Pilot Valve?
Check the pilot valve for smooth operation and clean any debris from internal components. Inspect seals for wear and ensure tight connections. Regular maintenance ensures accurate flow control and better performance in continuous operation without unexpected failures.
-
What are the common issues with the Hobart 404193-1 Pilot Valve?
- Valve is failing to open or close properly.
- Leakage due to worn internal seals.
- Restricted flow from debris buildup.
- Inconsistent pilot pressure control.