Vollrath 369075 Flame Sensor W/1-3/8" Probe 1/4" 90° TAB

SKU: 369075 Brand: Availability:
In Stock
(0)

C$ 27.44


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Specifications:

Attribute Details
Flame Sensor Probe, 1-3/8" Probe,
1/4" Tab Terminal 90 Degree.
Blodgett
Oven Mg32S, Mg3270, Mt2136G, Mt3255, Mt3855G, Mt3870.
Lincoln Oven Series 1000 (Except 1030) 1200
Middleby Marshall Oven Ps300, Ps350.

Description

The Vollrath 369075 Flame Sensor is a sensing component used to detect flame in appropriate combustion systems. The mechanism that it operates is by inserting its 1-3/8″ probe into the burner region, where it is able to detect heat or flame ionisation and relay this signal to the control system via the 1/4 inch 90 degree electrical tab. The sensor will then be placed in the prescribed burner mount in such a way that it will consistently know whether or not combustion has been established.

More Information:

  • BLODGETT:M0415||FRANKLIN CHEF:7912127||HENNY PENNY:81786||JOHNSON CONTROLS:Y75AA4||LANG:41100-07 ,LG41100-07||LINCOLN:369075||MIDDLEBY MARSHALL:27170-0018 ,M0415||VOLLRATH:369075 ,VOL369075

Step1: Turn off gas and electrical power at main supply, and allow oven to cool completely.

Step2: Remove access panel and locate old flame sensor near burner assembly.

Step3: Disconnect wiring harness and mounting tab carefully, noting original position.

Step4: Install new sensor in same orientation, secure tab mount to bracket.

Step5: Reconnect wiring firmly and restore electrical power and gas supply.

Step6: Test ignition cycle and verify flame detection for stable operation.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Vollrath/Idea-Medalie 369075 Flame Sensor?

    Inspect and clean sensor probe to remove grease and carbon buildup ensuring accurate flame detection. Check wiring and terminal connections for tightness and corrosion. Ensure proper alignment with burner flame and replace if signal weak.

  • What are common issues with the Vollrath/Idea-Medalie 369075 Flame Sensor?

    • No flame detection causing ignition lockout.
    • Intermittent signal loss due to loose or damaged wiring.
    • Sensor probe contamination affecting flame sensing accuracy.
    • Overheating or electrical contact failure leading to shutdown.