Tri-Star 300188 Fryer Natural Gas Safety Control Valve 7000 BMVR 3.5" WC

SKU: 300188 Brand: Availability:
In Stock
(0)

C$ 299.56 Price reduced from C$ 403.46
Save C$ 103.90


Have a Question? +1 (866) 963-0907 / (630) 326-8602

Specifications:

Attribute Details
Nat Gas Safety, 3.5" Wc, Model 7000 Bmvr, Mfg#700-506
3/4" Fpt In X 3/4" Fpt Out, Includes 3/4" X 1/2" Reducer
Bushings, Millivolt Actuator, Requires Wire Lead
Thermopile, 36" # 51-1121 Or 60" # 51-1257
1/4" Cct Pilot Out, 300,000 Btu
For Lp Conversion Use # 51-1470
Bakers Pride Oven Following Models Made After 10/94
Y600, Y800, Ds-805, Gs-805, D-125, 101, 151, 201
251, 301, 351, 3151, 401, 451, 4151, Fc-(516,616,816)
Cecilware Fryer Fmp-30, Fmp-40, Fmp-65, Fmp-403, Fms-30,
Fms-40, Fms-65.
Frymaster Fryer Models Made Before Feb. 1993 Gf14, Gf40,
J1C, Jcfx, J3Fc, J65X, Mj15, Mj35, Mj235, Mjcf.
Imperial Fryer Series If, Ihr, Ir.
Keating Fryer Gas Counter Units And Miraclean Griddles.

Description

The Tri-Star 300188 Safety Control functions as a safety partfor natural gas fryers to protect model 7000 BMVR. This control functions at 3.5" WC pressure to maintain performance while controlling gas flow and stopping dangerous situations. The main task of the Tri-Star 300188 Safety Control is to oversee burner operations by automatically cutting off gas supply when malfunctions occur to prevent fires or accidents. The fryer safety and efficiency increase because of this feature which gives operators a sense of security while reducing operational interruptions.

More Information:

  • ATOSA:301030003||BLOOMFIELD:DD-62193||CECILWARE:GML347A ,GML347F ,L347A ,L347F||DEAN:1896 ,807-0115 ,807-0306 ,807-2428 ,8070115 ,8070306 ,8072428 ,810-0014 ,8100014||ENTR?E:400042-1RS||FRYMASTER:1896 ,807-0115 ,807-0306 ,807-2428 ,807-3645 ,8070114 ,8070115 ,8070306 ,8072428 ,8073645 ,810-0014 ,8100014 ,FM1896 ,FM807-0115 ,FM807-0306 ,FM807-2428 ,FM8070114 ,FM8070115 ,FM8070306 ,FM8072428 ,FM810-0014 ,FM8100014||GARLAND:02511-1 ,1292799 ,2511 ,2511-1 ,F807-2425 ,F807-2428 ,F826-1580 ,GL1292799 ,GL2511||HOBART:00-348392-00001 ,00-353271-00001 ,110841-22 ,110841-23 ,348392-1 ,353271-1||IMPERIAL:1173 ,1173-RS ,1173RS ,IMP1173||JADE RANGE:8800000038||KEATING:2552 ,H00300H ,KEA2552 ,KEAH00300H ,P06066L||MARKET FORGE:93-0190||SOUTHBEND:1055997 ,1055999||STAR MFG:62193 ,DD-62193||TRI-STAR:300188 ,400042 ,AS-300188 ,TRS300188||U-LINE:343-701-400 ,343-811-400 ,700-506||VULCAN HART:110841-22 ,110841-23

Step1: Turn off gas fryer supply and disconnect power before servicing unit; ensure ventilation; verify compatibility.

Step2: Remove old valve and clean mounting area; inspect fittings and gas line.

Step3: Install new valve, align inlet/outlet, tighten fittings with proper sealant tape using approved method.

Step4: Reconnect lines, restore gas slowly, check for leaks with soap solution.

Step5: Test ignition and burner operation; ensure safety shutoff works and shutdown safety test.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Tri-Star 300188 Safety Control Valve?

    Inspect the gas safety control regularly for secure wiring, clean electrical terminals, and proper millivolt response from the thermopile. Check for gas leaks and ensure stable pressure during operation. Keep the valve free from grease buildup and verify accurate ignition and shutoff during service checks.

  • What are common issues with the Tri-Star 300188 Safety Control Valve?

    • Gas leakage due to worn seals.
    • Inconsistent flame or burner shutdown due to valve blockage.
    • Failure to open or close due to thermocouple malfunction.
    • Reduced gas pressure affecting heating performance.