Holman 2V-Z5104 1/2" FPT Natural/LP Solenoid Valve W/ 1/4" tab terminal

SKU: 2V-Z5104 Brand: Availability:
In Stock
(0)

C$ 294.06 Price reduced from C$ 396.07
Save C$ 102.01


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Specifications:

Attribute Details
[ Gas Nat/Lp ] [ 1/2" Fpt In/Out ] [ Nc ] [ 25 V ]
[ Width 3" ] [ 240,000 Btu ] [ 1/4" Tab Term ]
[ Brand Baso ] [ Mfg# H91Dg-2 ]
Imperial Oven Icv, Icv6 >2006, Icvg
Lang/Star
Grill G-(3Ei,4Ei,5Ei,6Ei)(All With S/N E51388 To E89816
And Beg With S/N F89817), Ggb-(24Ti,36Ti,48Ti)(All
With S/N D79600 And Above), G(3,4,5)Edsi.
Series G, Gc.

Description

The Holman 2V-Z5104 1/2" FPT Natural/LP Solenoid Valve delivers exceptional control in gas systems through its capabilities to operate reliably with natural gas and propane fuel sources. The valve delivers outstanding performance and durability because of its 240,000 BTU rating. The valve features 1/4" tab terminals for simple electrical wiring and works at 25V voltage with a safety-enhancing normally closed operation to stop gas flow during power off. The 3-inch wide design makes this valve suitable for installation across multiple setups such as Imperial Oven ICV models, Lang/Star grills and G series appliances.

More Information:

  • IMPERIAL:33885 ,36240||JOHNSON CONTROLS:H91DG-2||LANG:2V-80501-03 ,2V-80502-03 ,2V80502-03 ,80501-03 ,80502-03 ,LG2V-80502-03 ,LG2V80502-03 ,LG80502-03||STAR MFG:2V-80501-03 ,2V-80502-03 ,2V-Z5104 ,2V80502-03 ,80502-03||STERO:STA2V-80502-03 ,STA2V80502-03 ,STA80502-03

Step1: Turn off water/gas and electrical supply; relieve line pressure for safety and ensure isolation.

Step2: Remove the old valve threaded fittings; align the flow direction arrow and confirm orientation.

Step3: Install new valve inline and tighten securely without over-torquing; hand-tight then wrench snug.

Step4: Connect tab terminal to control wiring per system voltage and wiring diagram.

Step5: Restore supply slowly, check for leaks, cycle test, and check valve operation.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Holman 2V-Z5104 Natural/LP Solenoid Valve?

    Inspect the coil and electrical connections regularly for wear or corrosion. Clean the valve body to prevent debris buildup that can restrict flow. Ensure proper sealing and test operation periodically for accurate switching.

  • What are common issues with the Holman 2V-Z5104 Natural/LP Solenoid Valve?

    • Coil failure is preventing actuation.
    • Valve is are sticking due to debris buildup in internal passages.
    • Leaking seals causing pressure loss.
    • Electrical connector looseness or terminal corrosion.
    • Inconsistent opening under low pressure or gas switching issues.