Middleby Marshall 28091-0017 Oven Pilot Safety Valve W/ Reducing Bushings 3/4" FPT
Specifications:
| Attribute | Details |
|---|---|
| [ Gas Nat/Lp ] [ 1/2" Fpt Gas In/Out ] [ Nc ] [ 120 V] | |
| [ Width 3" ] [ 1/8" Fpt Low Flame Bypass ] | |
| Includes 1/8" Pipe Plug #26-2509. | |
| [ Brand Baso ] [ Mfg# H91Da-8 ] , | |
| 120 V Coil S-142, # 51-1167 | |
| Henny Penny Fryer 600, Og- 301,302,303 | |
| Lincoln Oven Where Applicable | |
| Middleby Marshall Oven Series | Ps200/222/224, Js250. |
| Ps250, Ps300, Ps310, Ps350, Ps360. |
Description
More Information:
- HENNY PENNY:38446||JOHNSON CONTROLS:H91DA-8||LINCOLN:100192||MIDDLEBY MARSHALL:28091-0017
Step1: Turn off the gas supply before starting installation.
Step2: Locate the pilot safety valve in the gas system.
Step3: Disconnect the oven thermocouple and gas line connections.
Step4: Remove the existing valve from its position.
Step5: Install the new valve with correct alignment.
Step6: Reconnect all fittings securely.
Step7: Restore gas supply slowly.
Step8: Check for leaks and proper pilot operation.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Middleby Marshall 28091-0017 Pilot Safety Valve?
Inspect the oven valve regularly for leaks, corrosion, or debris buildup. Clean components carefully and ensure proper seating of the valve. Check connections and test operation periodically. Always shut off gas or power before performing maintenance for safety.
-
What are the common issues with the Middleby Marshall 28091-0017 Pilot Safety Valve?
- Valve is failing to open or close properly.
- Gas leaks at the connection points.
- Sticking or sluggish valve movement.
- Inconsistent pilot ignition.