Garland 2195100-GAR Surface Heater 208V 1250W
Specifications:
| Attribute | Details |
|---|---|
| Garland Listed As 6-1/2" Element, 208V, 1250W. | |
| Surface Element, [ 208V 1250W ][ 6" Dia. Od Element ] | |
| [Terminals {Screw } | |
| Does Not Have Plastic Terminal End. | |
| Garland 680 Series After 12/92 | |
| 684, 684Rc, 686Rc, E22-12H, E684, E686 |
Description
More Information:
- GARLAND:2195100 ,2195100-GAR
Step1: Disconnect power at the breaker and allow the appliance to cool completely.
Step2: Remove the access panel to expose the surface element.
Step3: Disconnect wires from the old heater’s screw terminals.
Step4: Remove mounting brackets or clips and lift out the old element.
Step5: Position the new heater, secure it, and reconnect wiring firmly.
Step6: Restore power and test for even heating and proper operation.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Garland 2195100-GAR Surface Heater?
Inspect the heater element for debris, cracks, or discoloration. Ensure electrical connections are tight and free of corrosion. Test operation periodically, and disconnect power before performing any service.
-
What are the common issues with the Garland 2195100-GAR Surface Heater?
- Heater element burnout.
- Loose or corroded electrical connections.
- Uneven heating.
- Cracks or physical damage to the element.