The Garland 1920401 Thermocouple 72 inch GPD-48/60 is a temperature probe that is used in commercial ovens, namely GPD-48 and GPD-60. It is 72 inches long and it measures the presence of flames in the burner assembly and feeds necessary information to the gas control system of the oven. The thermocouple monitors the presence of the pilot flame and the correct operation and prevents the movement of unlit gas. It is installed directly in the combustion system, which helps to maintain a correct temperature and the stability of cooking performance.

More Information:

  • DYNAMIC COOKING SYSTEMS:13007-2||GARLAND:1920401||MARKET FORGE:10-6459||U-LINE:1980-072

Step1: Turn off gas supply and electrical power allow system to cool.

Step2: Remove access panel carefully.

Step3: Disconnect old thermocouple from control valve.

Step4: Position new thermocouple tip in pilot flame zone.

Step5: Secure mounting bracket tightly in place.

Step6: Reconnect wiring/gas connection securely.

Step7: Restore power and gas, then test ignition.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Garland 1920401 Thermocouple?

    Regularly inspect the thermocouple for soot, grease, or corrosion that can affect flame sensing accuracy. Ensure proper alignment with the pilot flame and secure mounting. Keeping it clean helps maintain accurate signal output. Always shut off the gas supply before performing any maintenance.

  • What are common issues with the Garland 1920401 Thermocouple?

    • Pilot flame not staying lit consistently.
    • Delayed response in flame detection.
    • Weak signal causing burner shutdown.
    • Improper positioning affecting performance.
    • Intermittent operation due to internal degradation.