Garland 1510402 Range Double Gum Valve 3/16" X 3/16"
Specifications:
| Attribute | Details |
|---|---|
| Dual Pilot Adjustment Valve | |
| [ 1/8" Mpt X 3/16" Cct ] [Width 1.25"], | |
| [ Comes With Twin 3/16" Cct ] | |
| American Range, Royal Range | |
| Bakers Pride Broiler Series | 50, Ch, Xx, Sgbr |
| Imperial Broiler Series | Eba, Gd, Icb, Irb. |
| Grill Series | Imga. |
| Range Series | Icra, Ispa. |
| Roaster Series | Ipr, Ipra. |
| Rankin-Deluxe Broiler Series | Drb. |
| Southbend Oven Series 400 | |
| Us Range Broiler Bbq-48, C-Hds-A(24,36,48). | |
| Gxc(24,36,48), Gxr(30,36,48,60) Series | Performer, Rg-Hds-A. |
| Wolf Broiler Cmss, Fcb, Scb. | |
| Range Ch, Chss. |
Description
More Information:
- AMERICAN RANGE:10432 ,A29301 ,AMRA29301||APW WYOTT:2065641||ATOSA:301030007||BAKERS PRIDE:2V-R3020A ,BKPR3020A ,R3020A ,R3020X||COMSTOCK CASTLE:25016||GARLAND:1150099 ,1510402 ,153844 ,GL1150099 ,GL1510402||HOBART:00-409557-00004 ,00-420786-00001 ,109557-4 ,120786-1 ,19190 ,409557-00004 ,409557-4 ,420786-00001 ,420786-1 ,6614 ,719190 ,806614||IMPERIAL:1003 ,1003-1 ,1608 ,IMP1608||RANDELL:CB-09 ,CB09 ,DRB-12 ,GT-10 ,RB-12 ,RDCB-09 ,RDCM-04 ,RDGM-14 ,RDHP-16A ,RDHP-E-C-16A ,RDLR-08A ,SP-14 ,SSPR-11 ,SUHP-10 ,SUHP-E-C-10 ,TB-12 ,TB-3-12 ,TB3-12||RANKIN DELUX:CB-09 ,CB09 ,DRB-12 ,GT-10 ,RANRB12 ,RANTB12 ,RB-12 ,RB12 ,RDCB-09 ,RDCM-04 ,RDGM-14 ,RDHP-16A ,RDHP-E-C-16A ,RDLR-08A ,SP-14 ,SSPR-11 ,SUHP-10 ,SUHP-E-C-10 ,TB-12 ,TB-3-12 ,TB12 ,TB3-12||ROYAL RANGE:053-AP6-1 ,0531-AP6-1 ,1211 ,53AP6-1 ,ROY053-AP6-1 ,ROY53AP6-1||SOUTHBEND:1166004 ,SOU1166004||VULCAN HART:00-409557-00004 ,00-420786-00001 ,00-719190 ,109557-4 ,120786-1 ,19190 ,409557-00004 ,409557-4 ,420786-00001 ,420786-1 ,6614 ,719190 ,806614 ,VH109557-4 ,VH409557-4 ,VH420786-1
Step1: Shut off the gas supply completely and allow the appliance to cool before working.
Step2: Remove the old pilot valve from the burner assembly, keeping track of orientation.
Step3: Install the new valve in the same position, securing all fittings tightly to prevent leaks.
Step4: Turn on the gas supply slowly and check all connections using a soap solution.
Step5: Ignite the pilot to verify proper operation and ensure it maintains a steady flame.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Garland 1510402 Pilot Valve?
Inspect the pilot valve in the cooking equipment for proper gas flow and ignition. Keep it clean and free of grease buildup. Check connections regularly and shut off the gas supply before performing maintenance for safety.
-
What are the common issues with the Garland 1510402 Pilot Valve?
- Pilot flame failing to stay lit consistently.
- Delayed ignition when starting the unit.
- Weak or unstable pilot flame.
- Gas flow irregularities affecting burner operation.
- Valve not opening properly during use.