Groen 13481 Oven High Limit Thermostat KX Dip Sealed 550°F Fixed 3/16" Bulb
Specifications:
| Attribute | Details |
|---|---|
| High Limt, Fixed Thermostat, | |
| [ Kx Dip Sealed ] [ Temp 550 Fixed ] | |
| [ Bulb 3/16" X 12-1/4" Nickel ] [ Cap 36" ] [ Mount 1 ] | |
| [ No Dial ] | |
| Groen Braising Pan Series | Chfp, Hfp, Nhfp. |
Description
More Information:
- GROEN:013481 ,13481 ,GR013481 ,GR13481 ,Z013481||U-LINE:5300-786 ,5300-78F ,KX61-36
Step1: Disconnect power and ensure oven is cool before starting.
Step2: Remove access panel carefully.
Step3: Note wiring and take a clear photo for reference.
Step4: Disconnect old thermostat and capillary bulb from mounting.
Step5: Insert new bulb into correct sensing tube position securely.
Step6: Mount thermostat securely to bracket.
Step7: Reconnect wiring per diagram or photo reference.
Step8: Restore panel and power, then test high-limit cutout operation.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Groen 13481 Thermostat?
Inspect the bulb and capillary for damage or leakage. Keep electrical terminals tight and free from corrosion. Verify temperature cutoff function during scheduled oven safety checks. Avoid bending the sensing bulb to maintain accurate high-limit protection and accurate operation.
-
What are common issues with the Groen 13481 Thermostat?
- Premature tripping is causing unexpected oven shutdowns during normal heating cycles.
- Faulty or inaccurate cutoff due to sensor calibration drift.
- Damaged or leaking capillary tube affecting temperature sensing.
- Electrical contact failure leading to no heating or constant cutoff.