Vulcan Hart 111497F1 Oven 3/8" Gas Solenoid Valve
Specifications:
| Attribute | Details |
|---|---|
| 3/8" Fpt Gas In/Out, Nat/Lp, With 1/8" Fpt Pilot Out, | |
| 120V, 121,000 Btu, Nc, Width 2", Robertshaw, .05A | |
| This Is New Style With "Black" Molded Coil | |
| Coil # 51-1361. | |
| American Range Oven Ar-3Rbc | |
| Cleveland Skillet Sgl-T, Sgm-T | |
| Dynamic Cooking Systems Oven Fsco. | |
| Garland Oven Series | Bco, Eco, Ico, Tg2/3/4, Ttg2/3/4. |
| Us Range Grill Tb-24Gg (Both Right & Left). | |
| Oven Series | Pilot & Burner Solenoid For 836 Cuisine, |
| 900 Phoenix, Performer Ii. | |
| Vulcan Hart Fryer Series | Gef-(M,Sm), Spg, Spgr. |
| Grill 900A | |
| Oven Tag77Fd.Series | 77 (Models 24,36,48,60,148,160,260, |
Description
More Information:
- CLEVELAND:G02965-1||DYNAMIC COOKING SYSTEMS:16110||GARLAND:1027300 ,227029-1 ,227029-2 ,227160 ,227160-1 ,227160-2 ,227160-3 ,227160-4 ,261589 ,G02965-1 ,G02965-3||HOBART:00-348047-1 ,00-411497-000F1 ,00-497094-00001 ,00-770085-00002 ,00-920608-00011 ,111497-F1 ,348047-1 ,411497-000F1 ,411497-F1 ,497094-00001 ,497094-1 ,770085 ,770085-00002 ,770085-2 ,920608-00011 ,920608-11||MARKET FORGE:93-0016||SAVORY:25008 ,25008SP||VULCAN HART:00-411497-000F1 ,00-497094-00001 ,00-770085-00002 ,00-920608-00011 ,111497-F1 ,111497F1 ,20608-11 ,411497-000F1 ,411497-F1 ,411497F1 ,497094-00001 ,497094-1 ,70085 ,770085 ,770085-00002 ,770085-2 ,920608-00011 ,920608-11
Step1: Turn off gas supply and disconnect electrical power to the appliance.
Step2: Remove access panel and carefully disconnect old valve wiring and gas lines.
Step3: Unscrew the faulty solenoid valve using proper wrench support.
Step4: Clean pipe threads and apply approved gas-rated sealant.
Step5: Install new solenoid valve in correct flow direction and tighten securely.
Step6: Reconnect wiring and ensure proper grounding.
Step7: Restore gas and power, then test for leaks and proper ignition operation.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Vulcan Hart 111497F1 Gas Solenoid Valve?
Regularly inspect the valve for gas leaks, corrosion, or debris buildup that could affect performance. Keep connections clean and tight. Ensure proper electrical function. Periodically test operation to confirm smooth opening and closing for secure, efficient gas flow.
-
What are common issues with the Vulcan Hart 111497F1 Gas Solenoid Valve?
- Valve failing to open or close properly.
- Gas flow interruption or inconsistency.
- Electrical coil burnout or malfunction.
- Internal sticking due to debris buildup.
- Gas leaks from worn seals or connections.
- Delayed ignition response in oven system.