Southbend 1099002 Gas Griddle Pilot Adjustment Valve W/1/8" MPT X 1/4" CCT 1-3/16" W

SKU: 1099002 Brand: Availability:
In Stock
(0)

C$18.33


Have a Question? +1 (866) 963-0907 / (630) 326-8602

Specifications:

Attribute Details
Pilot Adjustment Valve
[ 1/8" Mpt X 1/4" Cct ] [Width 1-3/16" ], Straight,
Adjustable

Description

The Southbend 1099002 Oven Pilot Adjustment Valve regulates the amount of gas that passes to the pilot burner by rotating an adjustable screw that changes the size of the gas opening, which enables one to set the pilot flame to a specific height. The adjustment mechanism closes or opens the internal valve as the adjustment mechanism is turned to alter the quantity of gas supplied to the pilot assembly. It has a 1/8 inch MPT inlet and a 1/4" compression outlet with a 1-3/16" body width. This valve is installed in the gas supply line.

More Information:

  • ANETS:P8901-78||BLODGETT:Z1099002 ,ZP2133||CECILWARE:F019A ,F019F ,GMF019A ,GMF019F||CHG:CHGG34-6460 ,G34-6460||COMSTOCK CASTLE:14ADJ ,25015 ,COM14ADJ ,COM25015||GARLAND:1086502 ,1086596 ,G03674-3 ,G6809 ,G6928-1 ,GL1086502 ,GL1086596 ,GLG03674-3 ,GLG6809||GRINDMASTER:F019A ,F019F||HOBART:00-404738-00003 ,00-719179 ,00-844516-00014 ,104738-3 ,404738-00003 ,404738-3 ,719179 ,802161 ,844516-00014 ,844516-14||JADE RANGE:4410400000||LANG:2V-70402-06 ,70402-06||MONTAGUE:01051-0 ,1051-0 ,22818-4 ,CB-6||PITCO:P8901-78||RANDELL:GB-05 ,HD GAS651 ,HDGAS651||RANKIN DELUX:GB-05||SOUTHBEND:1099002 ,P2133 ,SOU1099002 ,SOUP2133||STAR MFG:2V-70402-06 ,2V-70402-06 N ,2V-Y1177 ,Y1177||VULCAN HART:00-404738-00003 ,00-719179 ,00-844516-00014 ,104738-3 ,404738-00003 ,404738-3 ,719179 ,802161 ,844516-00014 ,844516-14 ,VH104738-3 ,VH404738-3 ,VH844516-14

Step1: Turn off gas and power supply and allow unit to cool completely before servicing.

Step2: Remove access panel and disconnect existing pilot adjustment valve carefully.

Step3: Apply approved thread sealant to fittings.

Step4: Install new valve, tightening securely without over-torquing connections.

Step5: Restore gas, check for leaks using soap solution, and test pilot flame adjustment.

Step6: Reassemble panel and verify safe operation.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Southbend 1099002 Pilot Adjustment Valve?

    Inspect and clean the pilot adjustment valve regularly to prevent carbon buildup and blockages. Check all fittings for gas leaks and ensure tight connections. Lubricate moving parts lightly to maintain smooth adjustment and safe operation.

  • What are common issues with the Southbend 1099002 Pilot Adjustment Valve?

    • Gas leakage from worn seals.
    • Pilot flame instability due to clogging.
    • Difficulty adjusting valve due to debris.
    • Corrosion in valve body.