Garland 1029410 Range Thermocouple 18" 20-30mV

SKU: 1029410 Brand: Availability:
In Stock
(0)

C$ 25.02 Price reduced from C$ 39.44
Save C$ 14.42


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Specifications:

Attribute Details
1980 Series Snap Fit 18" Thermocouple, 20-30 Mv
American Permanent Ware Griddle Ggm, Ggt
Comstock Castle Oven Bake, Barbeque & Pizza Ovens.
Series C, D, F, K.
Dynamic Cooking Systems Oven All
Garland Broiler 6-40/50S, 7-40/50S, 8-40/50S, 60-40/50R
Oven Series H281, P280. Standard Oven From 03/99 In
Canada Only, Range G20-Sph
Imperial Model?
Star Fryer M14, Mi4 (D,Dl), M18, Mi8(D,Dl), M43, 215B, 216,
403 404
Us Range Oven P-4-20.
Wolf Oven Ch, Chssd, R

Description

The Garland 1029410 Thermocouple 18 20-30mV is a sensing component is used to detect the existence of pilot flames in a range system. It works by producing a signal when heated and gas control circuit can maintain the correct flow when it is in operation. It is directly connected to the gas safety circuit and responds to the change of temperature at the point of flame. The system has a significant position in it as it is a vital support mechanism that aids in ignition accuracy, restricts gas interruption, and assists in maintaining stable range operation during regular cooking.

More Information:

  • AMERICAN RANGE:10485 ,A11100 ,AMRA11100||ANETS:ANEP8900-32 ,P8900-32||APW WYOTT:1473103 ,AS-1473103||CECILWARE:F002A ,F002F ,GMF002A ,GMF002F||COMSTOCK CASTLE:17005 ,COM17005 ,COMT46 ,T46||DYNAMIC COOKING SYSTEMS:13007 ,13007-01||GARLAND:1019418 ,1029410 ,1307401 ,1415000 ,227002 ,227122 ,227183 ,4518817 ,G01575-1 ,GL1019418 ,GL1029410 ,GL1415000 ,GL227183 ,GLG01575-1||HOBART:00-920325 ,14268 ,412788-1 ,714268 ,920325||IMPERIAL:1121 ,30030 ,IMP1121||JADE RANGE:460-126-000 ,4612600000 ,4620100000||ROYAL RANGE:2175 ,2179||SOUTHBEND:1163868 ,1683868 ,SOU1163868 ,SOU1683868||STAR MFG:2J-6726 ,2J6726 ,6726 ,H456||STERO:STA2J-6726 ,STA2J6726 ,STA6726 ,STAH456||TRI-STAR:310210 ,TRS310210||U-LINE:1980-018||VULCAN HART:00-920325 ,14268 ,412788-1 ,714268 ,920325

Step1: Turn off gas/electric supply and allow equipment to cool completely for safety.

Step2: Remove old thermocouple from pilot assembly carefully.

Step3: Position new thermocouple in same bracket, ensuring tip is in pilot flame path.

Step4: Secure connection to gas valve terminal and tighten firmly.

Step5: Restore supply and test ignition; check for stable flame and leaks.