Hatco 03.01.003.00 3" Dual Scale Pressure/temp Gauge W/ 2-1/2" Probe 1/2" MPT
Specifications:
| Attribute | Details |
|---|---|
| Dual Scale Pressure/Temp Gauge | |
| Size 3" Dia [Range 50-290F, 25-140C] [ 0-200 Psi ] | |
| [ 0-1400 Kpa ] Bottom Mount 1/2" Mpt, 2-1/2" Probe | |
| Temp Flagged At 285 Degrees |
Description
More Information:
- CHAMPION:101144||HATCO:03-01-003 ,03-01-003-00 ,03.01.003 ,03.01.003.00
Step1: Turn off system and release all pressure before installation.
Step2: Select suitable mounting port and clean internal threads.
Step3: Apply thread sealant tape to MPT connection.
Step4: Insert probe fully into process line or fitting.
Step5: Tighten gauge securely without over-torquing or damaging threads.
Step6: Align dial for clear visibility and readability.
Step7: Restore system pressure slowly and check for leaks; ensure readings stabilize safely before use.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Hatco 03.01.003.00 Temperature/Pressure Gauge?
Regularly inspect the gauge for inaccurate readings, moisture intrusion, or physical damage to the dial and probe connection. Verify the fitting remains secure and leak-free. Keep the gauge clean for clear visibility and ensure the sensing element stays properly positioned in the water stream.
-
What are common issues with the Hatco 03.01.003.00 Temperature/Pressure Gauge?
- Inaccurate pressure or temperature readings.
- Probe clogging or residue buildup.
- Leaking at connection.
- Fogged or cracked gauge lens.
- Calibration drift over time.