Vulcan Hart 00-428305-00001 Range Thermocouple 72" 20-30mV
Specifications:
| Attribute | Details |
|---|---|
| Heavy-Duty 72" Thermocouple, 20-30 Milevolt. | |
| Coaxial Thermocouple Threads = 11/32"-32 |
Description
More Information:
- BAKERS PRIDE:AS-M1296A ,BKPM1296A ,BKPM1296X ,M1296A ,M1296X||COOKING PERFROMANCE GROUP:351302170058||HOBART:00-428305-00001 ,428305-00001 ,428305-1 ,HOB00-428305-00001 ,HOB428305-00001 ,HOB428305-1||VULCAN HART:00-412788-00060 ,00-428305-00001 ,412788-60 ,428305-00001 ,428305-1 ,VH00-428305-00001 ,VH428305-00001 ,VH428305-1
Step1: Turn off gas supply and electrical power to range, allow appliance to cool completely before servicing.
Step2: Remove burner assembly or access panel to reach existing thermocouple connection at safety valve.
Step3: Disconnect old thermocouple from gas valve and pilot bracket, noting routing path.
Step4: Install thermocouple in same position, secure tip in pilot flame area, tighten connection to valve.
Step5: Restore gas supply, test ignition, and check for proper flame and no gas leaks using soapy water.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Vulcan Hart 00-428305-0000 Thermocouple?
Regularly inspect the thermocouple for signs of damage, corrosion, or loose connections. Clean the tip gently to remove grease or debris that may affect flame sensing. Ensure proper alignment with the pilot flame for accurate operation. Always turn off gas supply before servicing.
-
What are common issues with the Vulcan Hart 00-428305-00001 Thermocouple?
- Range failure to detect pilot flame properly.
- Weak or inconsistent millivolt output.
- Burner not staying lit after ignition.
- Loose or damaged connection points.
- Corrosion or buildup on thermocouple tip.