Vulcan Hart 00-424940-00001 Oven Cooling Axial Fan 120V 50/60Hz
Specifications:
| Attribute | Details |
|---|---|
| Axial Fan, 4-1/8" Sq Mt Ctrs, X 1-1/2" Wide, 120V, Cw, | |
| 12" Wire Leads, 106 Cfm, | |
| Alto-Shaam Asc-4G | |
| Vul424940-1 Oem Is Mechatronics | |
| Vulcan Oven Sg4C, Sg4D, Sg6C, Sg6D, Vc4Gs, Vc4Gd, Vc4Ec, | |
| Vc4Ed, Vc4Es, Vc6Gs, Vc6Gd, Vc6Ec, Vc6Ed, Vc6Es, | |
| Vc4Es, Vc6Gs, Vc6Gd, Vc6Ec, Vc6Ed, Vc6Es, | |
| Vc4Es, Vc6Gs, Vc6Gd, Vc6Ec, Vc6Ed, Vc6Es, |
Description
More Information:
- ALTO-SHAAM:ALTFA-3599 ,ALTFA3599 ,FA-3599 ,FA3599||HOBART:00-424940-00001 ,424940-00001 ,424940-1||VULCAN HART:00-424940-00001 ,424940-00001 ,424940-1 ,VH424940-1
Step1: Disconnect power and ensure oven is cool before starting.
Step2: Remove access panel and carefully take out old fan assembly.
Step3: Note wiring positions, then disconnect terminals carefully and safely.
Step4: Mount new axial fan securely, align bracket, and fasten properly.
Step5: Reconnect wiring per diagram, ensure insulation and safety compliance.
Step6: Refit panel, restore power, and test airflow operation.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Vulcan Hart 00-424940-00001 Cooling Axial Fan?
Clean oven fan blades and housing regularly to prevent grease buildup. Inspect wiring and motor connections for looseness or wear. Ensure proper ventilation and tighten mounting hardware to maintain stable operation and reduce vibration during use.
-
What are common issues with the Vulcan Hart 00-424940-00001 Cooling Axial Fan?
- Fan motor overheating or inconsistent speed due to electrical strain.
- Blade imbalance causing vibration and unusual noise.
- Wiring faults leading to intermittent operation or failure.
- Dust and grease buildup restricting airflow performance.