Vulcan Hart 00-414880-00001 Oven Thermostat K 5/16" X 8-1/16" 96" Cap

SKU: 00-414880-00001 Brand: Availability:
In Stock
(0)

C$325.10 Price reduced from C$437.87
Save C$112.77


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Specifications:

Attribute Details
[ Type - K ] [ Temp 200-400 ][ Bulb 5/16" X 8-1/16"
Nickel ] [ Cap 96" ] [ Mount 1 ]
Dial # 22-1353, Indicator Knob, 1-1/4" Dia, Flat Up Left.
Dial # 22-1191, Black T'Stat Knob W/ White Printed Numbers
[ 2" Dia ] [ Off-400-200] [Mount .187"] [Flat Down ].
Dial # 22-1006, [ 2" Dia ] [ Off-400-200]
[Mount .187"] [Position 4 Way]
Garland
Fryer 36Es-(11,11Bl,11Blsf,11Sf), 36Fs-21, 680-(31F,31Fbl),
780-(31F,31Sfbl), E22-(14F,28Ft), E24-(31F,31Sf).
Vulcan Fryer Vf, Vmf, Vtmf.
Welbilt Model ?

Description

The Vulcan Hart 00-414880-00001 Oven Thermostat that is specifically used for commercial cooking oven and designed for a lot of Welbilt fryer, precisely a lot of Welbilt fryer models. This thermostat operates in a temperature range of 200 to 400°F, and has a 5/16" x 8-1/16" capillary bulb with a 96" capillary length for flexible installation. Thermostat features a 1 1/4" diameter indicator knob that is flat for easy temperature adjustment, and a black thermostat knob with white numbers for easy visibility. This thermostat is one of the main benefits because it allows you to keep your cooking temperatures consistent so that you get optimal frying results and better food quality.

More Information:

  • HOBART:00-414880-00001 ,114880-1 ,24145-20 ,414880-00001 ,414880-1||U-LINE:5300-029 ,K250-96||VULCAN HART:00-414880-00001 ,105685-31 ,114880-1 ,24145-20 ,405685-31 ,414880-00001 ,414880-1 ,VH105685-31 ,VH114880-1 ,VH24145-20 ,VH405685-31 ,VH414880-1||WELBILT:B-2081

Step1: Turn off power and gas supply to oven for safety.

Step2: Remove control panel to access the thermostat assembly.

Step3: Label and disconnect wiring from old thermostat.

Step4: Carefully withdraw capillary tube from oven cavity without kinks.

Step5: Install new thermostat, routing capillary in original position.

Step6: Reconnect wiring, secure mounting, restore power, and test temperature calibration, check operation.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Vulcan Hart 00-414880-00001 Thermostat?

    Inspect the thermostat capillary tube and sensing bulb regularly for leaks, bends, or kinks that can affect temperature accuracy. Keep the bulb securely positioned inside the oven cavity and free from grease buildup. Ensure all electrical connections are tight and free of corrosion for stable operation.

  • What are common issues with the Vulcan Hart 00-414880-00001 Thermostat?

    • Capillary tube leaks or damage affecting sensing response.
    • Inconsistent heating cycles causing fluctuating cooking performance.
    • Stuck or failing electrical contacts disrupting thermostat operation.
    • Calibration drift resulting in inaccurate temperature readings.